22
en | Connection
AUTODOME IP starlight 5000i
2019-03 | 1.2 |
Installation Manual
Bosch Security Systems
9
Connection
!
Caution!
Compliance with EN50130-4 Alarm Standard – CCTV for Security Applications
To meet the requirements of the EN50130-4 Alarm Standard, an ancillary uninterruptable
power (UPS) supply is necessary. The UPS must have a
Transfer Time
between 2–6 ms and a
Backup Runtime
of greater than 5 seconds for the power level as specified on the product
datasheet.
Note
: Consult the National Electrical Code (NEC) for cable bundling requirements and
limitations.
4
Connect the cable to the 24 VAC wires from the camera.
Label ID
Description
Cable Wire Color
AC24V
24 VAC
Red
AC24V
24 VAC
Black
EARTH
Earth Ground
Yellow/Green
4
Connect the Ethernet cable to the RJ45 connector of the camera. The following figure
illustrates a typical system configuration.
1
2
3
4
1
2
2
4
Figure
9.1: AUTODOME IP System Config
1 AUTODOME camera
2 IP connection (Ethernet/CAT5/CAT6) (100 m maximum)
3 Network switch
4 Network device (computer with monitor, DVR/NVR, etc.)
4
If desired, connect the alarm and/or audio wires as identified in the following table.
Label ID
Description
Cable Wire Color
ALARM_COM
Alarm Communications Red
ALARM_OUT
Alarm Out
Brown
Summary of Contents for AUTODOME IP starlight 5000i NDP?5512?Z30C
Page 1: ...AUTODOME IP starlight 5000i NDP 5512 Z30C en Installation Manual ...
Page 2: ......
Page 29: ......