64
en | Network
AUTODOME IP 4000i
2020-06 | 2.0 |
User Manual
Bosch Security Systems
Status
The status of the DynDNS function is displayed here for information purposes. You cannot
change any of these settings.
9.4
Advanced
The settings on this page are used to implement advanced settings for the network.
Cloud-based services
Operation
The operation mode determines how the camera communicates with the Bosch Remote
Portal.
–
Select
On
to poll the server constantly.
–
Select
Off
to block polling.
Cloud state
This field identifies any cloud-based services with which the camera communicates.
–
If you have registered the device on a cloud-based service such as Bosch Remote Portal,
then this field identifies this fact (“
Registered on Bosch Remote Portal
”).
Note
: The button (
Connect to Bosch Remote Portal
) to connect to the device with that
service is active.
–
If you have not registered the device, then the message, “
Not running
.
(Automatic IP
assignment not active)
“ appears.
Note
: The button (
Connect to Bosch Remote Portal
) to connect to the device with that
service is not active.
Stratocast
Enter the Stratocast
Registration code
to connect with the Genetec’s Stratocast cloud.
Click
Register
to activate the account.
RTSP port
If necessary, select a different port for the exchange of the Real Time Streaming Protocol
(RTSP) data from the list. The standard
RTSP port
is 554. Select
Off
to deactivate the RTSP
function.
Authentication
If a RADIUS server is employed in the network for managing access rights, authentication must
be activated here to allow communication with the unit. The RADIUS server must also contain
the corresponding data.
To configure the unit, you must connect the camera directly to a computer using a network
cable. This is because communication via the network is not enabled until the
Identity
and
Password
parameters have been set and successfully authenticated.
Identity
Enter the name that the RADIUS server is to use for identifying the camera.
Password
Enter the password that is stored in the RADIUS server.
TCP metadata input
TCP port
The device can receive data from an external TCP sender, for example an ATM or POS device,
and store it as metadata. Select the port for TCP communication. Select Off to deactivate the
TCP metadata function.
Sender IP address
Enter the IP address of the TCP metadata sender here.
Summary of Contents for AUTODOME IP 4000i NDP-4502-Z12
Page 1: ...AUTODOME IP 4000i NDP 4502 Z12 NDP 4502 Z12C NDP 45A2 Z12C NDP 45A2 Z1 2CY en User Manual ...
Page 2: ......
Page 75: ...AUTODOME IP 4000i Troubleshooting 75 Bosch Security Systems User Manual 2020 06 2 0 ...
Page 76: ...76 Troubleshooting AUTODOME IP 4000i 2020 06 2 0 User Manual Bosch Security Systems ...
Page 77: ......