![Bosch AMC2-4R4 Installation Manual Download Page 41](http://html.mh-extra.com/html/bosch/amc2-4r4/amc2-4r4_installation-manual_39650041.webp)
Connecting Relay Outputs
To operate locks or alarm systems, the AMC2-4R4 has eight
form C relay outputs. The outputs will be connected to the 3-pin
pluggable screw connectors S5, S6, S10, S11, S17, S18, S22,
and S23 - refer to Connecting Diagrams, page 58.
Figure 4.19: Location of the relay output connectors
Each relay output can operate in ‘wet’ mode, using the
AMC2-4R4's internal 12/24 Vdc power supply for external
devices or ‘dry’ mode with potential free contacts for externally
powered systems.