AMAX panel 2000 / AMAX panel 2000 EN
Technical Data | en
77
Bosch Sicherheitssysteme GmbH
Installation Manual
F.01U.241.127 | V4 | 2011.12
9.2
Interface Description
9.2.1
Terminals Internal Description
9.2.2
Connector Interface Description
Terminal
Description
18 VAC
These two terminals are the plug-on type and are the terminal points for the
transformer. To ensure correct operation, the voltage of the transformer must
be 18 VAC to 22VAC at 1.3 A (minimum)
+BATTERY
–BATTERY
The + Battery terminal connects to the Red positive lead of the battery and the
– Battery terminal connects to the black negative lead of the battery. The
battery should be a 12 VDC sealed lead-acid rechargeable type with a 7 AH
capacity.
OC +
OC2OC1
The group of terminals provides 2 programmable open collector outputs; the
Maximum rated current is 500 mA for each OC output, with overload and short
circuit protection function.
+12V
GND
Independent Power output, +12 V is the positive polarity and GND is negative
polarity.Output voltage: 13.5 VDC +3%/-5% (at AC power), 10 VDC ~ 13.7 VDC
(only battery power) , the Maximum rated current is 500 mA, with overload
and short circuit protection function.
R
B
G
Y
The group of terminals is OPTION bus interface terminals; connect with the
external option bus module such as IUI-AMAX-LED/LCD keypad, DX3010
module. R is power + and B is power -, G is data out and Y is data in. R and B
can be regarded as another independent power output. Output voltage: 13.5
VDC +3%/-5% (at AC power), 10 VDC - 13.7 VDC (only battery power), the
Maximum rated current is 500 mA, with overload and short circuit protection
function.
Z1-Z8
COM
These terminals are provided to zone detectors.
TIP
TIP1
RING1
RING
These terminals are provided for telephone line connection.
TIP and RING are connected to external telephone line input.
TIP1 and RING1 are connected to housing telephone line.
Connection Description
P3
Connector
+5V RFIN
GND
The Connector is for RF receiver connection. +5V and GND provides a 5 VDC
power to WE 800 E RF receiver. RFIN is data in from WE 800 E RF receiver.
P7/OC3
Connector
The Connector provides one programmable open collector output. The
maximum rated current is 100mA
P8
Connector
The Connector is for tamper switch input.