AMAX panel 2000 / AMAX panel 2000 EN
Technical Data | en
75
Bosch Sicherheitssysteme GmbH
Installation Manual
F.01U.241.127 | V4 | 2011.12
9
Technical Data
9.1
Specification
Panel
Enclosure :
Dimensions (HxWxD):
–
260mm x 280mm x 83,5mm
Weight: –
1950g
Environmental Considerations :
Relative Humidity:
–
10%-95%
Operating Temperature:
–
-10°C - +55°C
Supervised Zones:
Onboard:
Z1 - Z8 COM
–
8 Single or dual end-of-line (EOL 2,2KΩ) tamper point
support
P8 Tamper
–
Enclosure tamper input (does not reduce point capacity)
Programmable Outputs (PO):
Onboard:
OC 1
–
supervised output max 500mA
OC 2
–
supervised output max 500mA
OC 3
–
max 100mA
Auxiliary module
(DX3010):
Relay 1-8
–
Contacts rated 5A at 28VDC
Cable requirements:
–
Unshielded and shielded 0,6-0,8mm
Number of...
Users:
–
16 (8 + 8Keyfob)
Key Fobs:
–
8
Events:
–
254 history events, stamped with time and date
–
254 EN history events, stamped with time and date
Pin Code variations
–
10000
DX 3010:
–
1
B 420 or DX 4020 or DX
4020 G
–
1
Keypads:
–
2
Power:
Power Supply Type:
–
A
Transformer:
–
230V Input/18VAC 20VA Fuse=500mA
AC Input:
–
AC Input Voltage: 195 VAC to 253 VAC
–
Line Voltage Frequency: 50 Hz
DC Output:
–
maximum current for all components 1100mA
–
maximum current for all components 550mA (recharge Batt
80% in 72h)