AMAX panel 2000 / AMAX panel 2000 EN
Fault and Tamper Description | en
31
Bosch Sicherheitssysteme GmbH
Installation Manual
F.01U.241.127 | V4 | 2011.12
1.
Report the keypad fault to the configured destination programmed on location 140.
2.
Flash FAULT indicator on the other keypad in normal operation (refer to the detailed
description in chapter keypad indicators).
3.
Keypad missing communication with the panel performance as below:
–
Stop detection on the keypad button
–
Flash FAULT indicator
–
The disconnected keypad do not sound FAULT beeping per minute
4.
When the keypad fault is reset, send the restore report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
5.1.2
Keypad 2 fail
Condition:
1.
Keypad fail is reported at any time when communication fails between the panel and
address 2 keypad.
Restore:
Communication between panel and keypads comes back to normal and fault is reset.
Supervise:
1.
Report the keypad fault to the configured destination programmed on location 140.
2.
Flash FAULT indicator on the other keypad in normal operation (refer to the detailed
description in chapter keypad indicators).
3.
Keypad missing communication with the panel performance as below:
-Stop detection on the keypad button
-Flash FAULT indicator
-The disconnected keypad does not sound FAULT beeping per min
4.
When the fault is reset, send the restore report to the configured destinations of the
control panel system. The FAULT indicator is turned off when there is no other system
fault.
5.1.3
DX3010 Fail
Condition:
No communication with DX3010 if DX3010 is programmed.
Restore:
Communicaiton with DX3010 is normal and fault is reset.
Supervise:
1.
Report the DX3010 fault to configured destination on location 140 when the fault is
detected.
2.
Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
3.
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
5.1.4
B420/DX4020/ITS-DX4020G Fail
Condition:
No communication with the DX4020/ITS-DX4020G if DX4020/ITS-DX4020G is programmed.
Restore:
NOTICE!
Keypad 2 fail is only reported when Keypad 2 was connected during powering up the system!