40
| Controls
6 720 813 643 (2018/04)
5.6
Service menu - AU Technical Settings
Accessing the AU Technical Settings menu
▶ Touch the symbol
.
Display shows
P4 Information
.
▶ Touch symbols
or
to select
AU Technical Settings
menu.
▶ Touch the symbol
.
Display shows Technical Settings menu (password input).
▶ Select the password (1886).
Authentication completed.
▶ Touch the symbol
.
Access to
installer exclusive menus
.
•
P0 - Min. Power
•
P1 - Maximum Power
•
P2 - Minimum Power
•
UC - Combustion Auto Adjust
•
P7 - Gas Type (LPG, NG)
•
LM - Temperature Limited
•
PE - Appliance Type
•
PF - Bypass (On / Off)
•
PA - Actuator Calibration
•
RS - Recirculation Settings
•
IC - ICC
LM Temperature Limited
Unlock the Temperature Limit
▶ Touch the symbol
.
Display shows following menu.
–
Unlocked
–
Locked
The current selection is in green color.
▶ Touch symbols
or
to select
Unlocked
.
▶ Touch the symbol
.
▶ Touch the symbol
to return to main menu.