Installation instructions
TR1000 4 T, TR1000 5 T, TR1000 6 T, TR1000 6 B – 6 720 876 020 (2020/06)
20
3
Installation instructions
Install the continuous-flow heater as described in the
illustrated section. Observe the instructions in the text.
3.1
Installation
I. Unpacking/scope of supply
•
Unpack the appliance and check for transport damage.
•
Dispose of the packaging and, where applicable, the old
appliance, in an environmentally conscious manner.
3.1.1 Preparation for installation
CAUTION:
Important!
Only use the enclosed installation set.
•
Shut off water supply. The electrical connection
(connection cable) must be disconnected from the power
supply. Unscrew the fuse or switch off the circuit breaker.
•
There must be a clearance of approximately 60mm on all
sides of the appliance for installation.
•
Observe the technical data for the appliance.
•
TR1000 5 T, TR1000 6 T, TR1000 6 B:
Unscrew
the screws on the housing cover and remove the lid.
II. Wall mounting
•
Secure the appliance using the installation template,
screws and wall plugs so that it is vertical and flush against
the wall:
•
TR1000 5 T, TR1000 6 T, TR1000 6 B:
For an exposed
electrical connection, the different methods of routing the
supply line found on the assembly template must be
observed.
•
TR1000 5 T, TR1000 6 T, TR1000 6 B:
The sleeve must fit
tightly round the connection cable. If the sleeve is damaged
during installation, the holes must be sealed water-tight.
III. Water connection
A
Pressurised connection
•
For a pressurized connection, the tap and outlet fittings
must be approved for operation with closed (pressurized)
continuous-flow heater system.
B
Depressurised connection
•
Fit the jet regulator supplied.
•
Check the inserted filter and sleeve in the water inlet.
•
Ensure that the connection pipes are fitted to the adapter
along the axis of the pipes.
•
Tighten the union nuts firmly to the adapter with an open-
jawed spanner.
The T-piece and flexible connecting hose (for pressurised
connection) are available from a specialist store.
For a depressurised connection, a depressurised fitting must
be used, e.g. fitting BZ13051 which can be obtained as
a special accessory.
IV. Electrical connection
C
Flow switch
D
Temperature limiter
•
TR1000 4 T:
Connect the appliance to the mains.
TR1000 5 T, TR1000 6 T, TR1000 6 B
The installation of non plug-in ready appliances must be
undertaken by the respective utility operator or by a qualified
specialist company, who can also assist you when you are
requesting the approval of the utility company for installation
of the appliance.
The appliances must be connected with a NYM-J3x4 (mm
2
)
mains lead. Leads with a larger cross-section must not be used.
•
Connect the appliance in accordance with the connection
diagram on the strip terminal.
•
Screw the housing cover back on.
•
After installation, give the user the operating
instructions and explain how the appliance works.
TR1000 6 B
High level appliance
TR1000 4 T
TR1000 5 T
TR1000 6 T
Under counter appliances
1
Housing
2
Mounting (2 screws, 2 wall plugs)
3
ON indicator (only on the TR1000 6 B)
4
Filter and sleeve (inserted in inlet)
5
Jet regulator and seal
6
Only for appliances with a permanent electrical
connection: Rubber grommet
1
Locate the appliance on the screw and press down.
2
Screw in the second screw through the mounting
tab and tighten.
Summary of Contents for 7736504716
Page 68: ...68 Гарантія TR1000 4 T TR1000 5 T TR1000 6 T TR1000 6 B 6 720 876 1 2 ...
Page 69: ...69 Гарантія TR1000 4 T TR1000 5 T TR1000 6 T TR1000 6 B 6 720 876 3 ...
Page 70: ...70 Гарантія TR1000 4 T TR1000 5 T TR1000 6 T TR1000 6 B 6 720 876 4 ...
Page 71: ...71 Гарантія TR1000 4 T TR1000 5 T TR1000 6 T TR1000 6 B 6 720 876 ...
Page 72: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...