Borri B 200 User Manual Download Page 2

Installation & Operation 

 

Initial Set-up

 

After unpacking the unit, please avoid placing the unit in direct sun light, excessive heat, 

excessive humidity or in contact with fluids of any type. Please allow 20cm space around the 

unit. 

 

 

 

 

 

Connect Mains Power

 

Plug the UPS into an electrical outlet that does not share a circuit with a other heavy electrical 

load. Please allow the UPS to charge at least 6 hours prior to use. 

 

 Connect Equipment 

Connect critical equipment to the battery backup outlets; these are supported automatically by 

the battery when a mains failure occurs. Connect other equipment that needs only surge 

suppression to the surge protected outlets. Power is not supplied to these outlets when the 

unit is switched off. Therefore, please be sure to switch on the unit. 

NOTE: Please DO NOT connect scanners or printers to the battery backup outlets. 

 

Connect Modem/Phone/Network for Surge Protection

   

Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of the 

UPS unit. Connect from “OUT” outlet to the computer with another phone line cable. 

 

Connect Communication Port 

To allow for unattended UPS shutdown/start-up and status monitoring, connect the 
communication cable one end to the USB port and the other to the communication port of your 
PC. With the monitoring software installed, you can schedule UPS shutdown/start-up and 
monitor UPS status through PC. 
 

Software Installation 

1) Please download the monitoring and shutdown software from the website 

http://www.borri.co.uk/softwaredownload

 

to download ViewPower software.     

2) When your computer restarts, the monitoring software will appear as an orange plug icon 

located in the system tray, near the clock. 

 
Power On/Off UPS 

Press power switch on the front panel of the UPS to turn on the UPS. Press switch again to turn 

off the UPS. 

 

Front Panel & Back Panel 

            LCD panel 

 

        Power switch 
 

 

B200-1000 

B200-1500/2000 

 

Troubleshooting 

Problem 

Possible Cause 

Solutions 

The front panel in blank. 
 

Low battery. 

Charge the UPS at least 6 hours. 

Battery fault. 

Replace the battery with the same 
type of battery. 

The UPS is not turned on. 

Press the power switch again to turn 
on the UPS. 

Alarm sounds 
continuously when the   
mains is normal. 

The UPS is overload. 

Remove some loads first. Before 
reconnecting equipment, please 
verify that the load matches the UPS 
capability specified in the specs. 

When power fails, 
back-up time is short. 

The UPS is overload. 

Remove some critical load. 

Battery voltage is too low. 

Charge the UPS at least 6 hours. 

Battery defect. It might be due 
to high temperature operation 
environment, or improper 
operation to battery. 

Replace  the  battery  with  the  same 
type of battery. 

The mains is normal but 
UPS is on battery mode. 

Input power cable is loose. 

Reconnect  the  input  power  cable 
properly. 

 

LCD Panel:   

 

 Input voltage                   

 Load level indicator, flashing   

 Output voltage                        indicates overload 

 AC mode indicator           

 Battery capacity indicator, flashing 

 Battery mode indicator            indicates low battery 

Battery backup receptacles 

Surge protected receptacles 

AC input 

USB communication port 

Modem/Phone Line/Network 

surge protection

 

 