background image

Split Air Conditioner

Thank you for choosing our product.

For proper operation, please read and keep this manual carefully. 

If you have lost the Owner’s Manual, please contact the local agent or visit

 www.borealintl.com or sent email to [email protected] for electronic version.

BRS

12

HPL1IA

Summary of Contents for Brisa BRS12HPL1IA

Page 1: ...ur product For proper operation please read and keep this manual carefully If you have lost the Owner s Manual please contact the local agent or visit www borealintl com or sent email to borealsales borealintl com for electronic version BRS12HPL1IA ...

Page 2: ...BRS12HPL1IA ...

Page 3: ...allation 29 Selection of installation location 29 Requirements for electric connection 30 Installation Installation of indoor unit 31 Check after installation 36 Test and operation Test operation 36 Attachment 37 Pipe expanding method 39 Safety precautions for installing and relocating the unit 28 This appliance is not intended for use by persons including children with reduced physical sensory or...

Page 4: ...njury or property loss is caused by the following reasons Indicates a hazardous situation that if not avoided will result in death or serious injury Indicates a hazardous situation that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related information used to indic...

Page 5: ...of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision conditioner Otherwise it may cause electric shock If the supply cord is damaged it must be replaced by electric shock shock or malfunction ...

Page 6: ...damage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill water on the remote controller otherwise the electric shock or damage Please contact dealer when you need to repair air conditioner Do not repair air conditioner by yourself It may cause object...

Page 7: ...k fire hazard or malfunction Please install proper power supply cables before using the air conditioner Properly connect the live wire neutral wire and grounding wire of power socket Be sure to cut off the power supply before proceeding any work related to electricity and safety Don t use unqualified power cord Installation must be performed by qualified professionals Otherwise it may cause person...

Page 8: ...onnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The air conditioner is the first class electric appliance It keep the interconnection cable away from the copper tube The temperature of refrige...

Page 9: ...ther must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be 5 Instructions for installation and use of this product are provided by the manufacturer expressly approved by the party responsible for compliance could void the user s authority to operate the equipm...

Page 10: ...ons FCC STATEMENT accordance with the instructions may cause harmful harmful interference in a residential installation This undesired operation frequency energy and if not installed and used in However there is no guarantee that interference will does cause harmful interference to radio or television correct the interference by one or more of the following measures equipment off and on the user i...

Page 11: ...h Industry Canada licence This equipment complies with FCC s and IC s RF radiation exposure limits set forth for an uncontrolled environment The antenna s used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause not be c...

Page 12: ...only unit is 8 IC STATEMENT antennes utilisées pour cet émetteur doivent être installées et doivent fonctionner à au moins 20 cm de distance des utilisateurs et ne doivent pas être placées près d autres antennes ou émetteurs ou fonctionner avec ceux ci Les installateurs doivent s assurer qu une distance de 20 cm sépare l appareil à l exception du combiné des utilisateurs NOTICE 18 1 F 46 1 115 F f...

Page 13: ... content or position may be different from above graphics please refer to actual products panel aux button horizontal louver air outlet NOTICE Actual product may be different from above graphics please refer to actual products remote controller ...

Page 14: ...ls drying indicator display For some models For some models indicator heating temp indicator cooling indicator power indicator receiver window drying display For some models heating indicator temp indicator cooling indicator power indicator receiver window drying indicator G W R Power LED color indicator Green status ON Red status OFF Red R Heat Mode Mode LED color indicator White W Cool Mode Gree...

Page 15: ...ion mode I feel WiFi This is a general remote controller Some models have this function while some do not Please refer to the actual models Buttons on remote controller Introduction for icons on display screen 6 3 7 9 10 14 15 13 12 8 11 5 4 2 1 1 ON OFF button 2 MODE button 3 FAN button 4 TURBO button 6 button 7 button 9 I FEEL button 13 LIGHT button 14 15 TEMP button 11 CLOCK button 12 WiFi butt...

Page 16: ...eneral use remote controller it could be used for the air conditioners with multifunction For some function which the model doesn t have if press the corresponding button on the remote controller that the unit will keep the original running status els Press or button to adjust set temperature Press FAN button to adjust fan speed Press button to adjust fan blowing angle When selecting dry mode the ...

Page 17: ...remote controller will change quickly On releasing button after setting is finished temperature indica tor on indoor unit will change accordingly Temperature can t be adjusted under It s Low fan speed under Dry mode This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould Having set X FAN function on After turning off the unit by pre...

Page 18: ...m angle When selecting air conditioner is blowing fan at fixed position Horizontal louver will stop at the fixed position When selecting air conditioner is blowing fan at fixed angle Horizontal louver will send air at the fixed angle Hold button above 2s to set your required swing angle When reaching your required angle release the button Note may not be available When air conditioner receives this si...

Page 19: ...object of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature T ON button T ON button can set the time for timer on After pressing this button icon disappears and the word ON on remote controller blinks Press or button to adjust T ON setting After each pressing or button T ON setting will increase or decrease 1min Hold or button 2s later the time will cha...

Page 20: ...ore to factory default setting 16 12 Introduction for buttons on remote controller Press this button to set clock time icon on remote controller will blink Press or button within 5s to set clock time Each pressing of or button clock time will increase or decrease 1 minute If hold or button 2s later time will change quickly Release this button when reaching your required time Note Clock time adopts...

Page 21: ...r on indoor unit displays set temperature When selecting with remote controller temperature indicator on indoor unit displays indoor ambient temperature When selecting with remote controller temperature indicator on indoor unit displays outdoor ambient temperature Note Outdoor temperature display is not available for some models At that time indoor unit receives signal while it displays indoor set...

Page 22: ...MP and CLOCK buttons simultaneously to start up or turn off 8 heating function When this function is started up and 8 will be shown on remote controller and the air conditioner keep the heating status at 8 Press TEMP and CLOCK buttons simultaneously again to exit 8 heating function Note Under 8 heating function fan speed is defaulted at auto speed and it can t be adjusted Under 8 heating function ...

Page 23: ...more than 8m and there should be no obstacles between them Signal may be interfered easily in the room where there is fluorescent lamp or wireless telephone remote controller should be close to indoor unit during operation Replace new batteries of the same model when replacement is required When you don t use remote controller for a long time please take out the batteries If the display on remote c...

Page 24: ...nditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not use volatile liquid to clean the air conditioner Do not use liquid or corrosive detergent clean the appliance and do not splash water or other liquid onto it otherwise it may damage the plastic components even cause electric shock Do not remove the panel when cleaning it WARNING Use insulated obje...

Page 25: ...nd then put it in a shady and cool place to dry panel cover tightly The filter should be cleaned every three months If there is much dust in the operation environment clean frequency can be increased After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard WARNING ...

Page 26: ...inage pipe is damaged 1 Disconnect power supply Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air conditioner please contact local dealer or consultant service center for the correct disposal method NOTICE Checking before use season NOTICE Checking after use season ...

Page 27: ...room Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit Check the batteries If the power of batteries is too low please replace them Take the remote controller close to indoor unit Turn off the fluorescent lamp and then try it ag...

Page 28: ...or temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper ature can t be adjusted Unit is operating under auto mode Temperature can t be adju sted under auto mode Please switch the operation mode if you need to adjust temperature Your required temperatur...

Page 29: ...less devices etc Disconnect power put back power and then turn on the unit again Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of refrigerant flowing inside the unit which is a normal phenomenon Cracking noise Air conditioner is turned on or turned off just now This is the sound of friction caused by expansion and or contraction of panel or other pa...

Page 30: ...be eliminated after restarting the unit If not please U8 It can be eliminated after restarting the unit If not please contact qualified professionals for service When below phenomenon occurs please turn off air conditioner and discon for service Power cord is overheating or damaged There s abnormal sound during operation Air switch trips off frequently Air conditioner gives off burning smell Indoo...

Page 31: ...27 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm Space to the wall Space to the wall At least 15cm ...

Page 32: ...ry make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is not yet connected air will be sucked in and cause pressure rise or compressor rupture resulting in injury When installing the unit make sure that connection pipe is securely connected before the comp...

Page 33: ...nner 14 Measuring tape Note 5 Pipe expander 8 Pipe cutter 11 Pressure meter Please contact the local agent for installation 3 Impact drill 6 Torque wrench 9 Leakage detector 12 Universal meter Don t use unqualified power cord Indoor unit 1 The place with strong heat sources vapors flammable or explosive gas or 2 The place with high frequency devices such as welding machine medical volatile objects s...

Page 34: ...der to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations 10 Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only 1 The air conditioner is the first class electric appliance It m...

Page 35: ...ease drill another fixing hole nearby 1 Step two install wall mounting frame Hang the wall mounting frame on the wall adjust it in horizontal position with the Left Wall Right Rear piping hole Wall Space to the wall above 150mm Space to the wall above 150mm Rear piping hole 18K 230V Φ55mm Φ2 1 4 Φ70mm Φ2 3 4 Φ55mm Φ2 1 4 Φ70mm Φ2 3 4 Level meter 12K 115V Left Wall Right Mark in the middle of it Le...

Page 36: ...nion nut with torque wrench the hole When select leading out the pipe from left or right please cut off the corresponding hole on the bottom case left right 1 The pipe can be led out in the direction of right rear right left or rear left left rear left right rear right Step four outlet pipe Installation of indoor unit Indoor 5 10 outdoor Φ55 Φ70 pipe joint union nut pipe Note Pay attention to dust...

Page 37: ... 40 45 55 60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pipe Note Add insulating pipe in the indoor drain hose in order to prevent condensation The plastic expansion particles are not provided 1 Open the panel remove the screw on the wiring cover and th...

Page 38: ...back and then tighten the screw 5 For the air conditioner without plug an circuit break must be installed in the line 34 cable cross hole power connection wire 09K 12K 18K 24K 3 red brown yellow green 4 Note Close the panel All wires of indoor unit and outdoor unit should be connected by a professional for a new one Avoid extending the wire by yourself installation The circuit break should be all ...

Page 39: ...eparately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with seal...

Page 40: ...damaging the parts Is there any obstruction in the air inlet Is the inlet and outlet of piping hole been covered and outlet heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connection pipe are open completely heating capacit It may cause insufficient cooling heating capacity or waster elet...

Page 41: ... Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet capacity After the length of connection pipe is prolonged for 10m at the basis of standard length you should add 5...

Page 42: ...0A and R134a Diameter of connection pipe Liquid pipe mm Gas pipe mm Φ6 Φ6 or Φ9 52 Φ12 Φ16 Φ19 Φ22 2 Φ9 52 or Φ12 Φ16 or Φ19 Φ19 or Φ22 2 Φ25 4 or Φ31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 120 120 50 20 Outdoor unit throttle ...

Page 43: ...g pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander Note A is different according to the diameter please refer to the sheet below expander hard mold pipe F Inspection Check the quality of expanding port If there is any blemish expand the port again accord...

Page 44: ...Boreal International a Watsco Inc subsidiary borealsales borealintl com www borealintl com 10300 NW 19th St 105 Doral FL 33172 786 621 8250 66129935317 ...