![bora XBO Operating And Installation Instructions Download Page 34](http://html1.mh-extra.com/html/bora/xbo/xbo_operating-and-installation-instructions_2788233034.webp)
EN
84
Installation
www.bora.com
Installation depth without frame spacer
21
46
21
≥30
≥
588
x
558
≥30
Fig. 9.3
Installation dimensions without frame
spacer
Installation depth with one frame spacer
33
46
546
≥
576
x
≥30
≥30
Fig. 9.4
Installation dimensions with one frame
spacer
adjacent element (unobstructed ventilation cross-
section [2]). Shorten the shelves if necessary.
X
So that the fill level is detected correctly, use a
spirit level to precisely adjust the shelf on which
the appliance is to sit.
9.5
BORA X BO frame spacer
The frame spacers can be used to vary the
appliance installation depth. The appliance is already
fitted with a frame spacer. Depending on where it is
installed, the 4-piece frame spacer can be removed
or an additional one can be fitted (available as
accessory X BO frame spacer XBORS).
i
For greater accessibility, the frame spacer
should be removed/fitted before installing
the appliance.
1,5
1
1
590
580
595
599
1,5
9
46
Fig. 9.2
Appliance dimensions
[1]
Frame spacer