3B-390978NU – 10/18
Page 9
EN
BONNET GRANDE CUISINE
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
19 ERROR MESSAGES
Message on the screen
Consequences
What to do?
i31 : Electronics overheating: Temperature reduced
to 180°C
Cooking continues automatically
at a temperature below 180°C
Clean the lower and rear air intakes. If the problem persists, call
a service technician.
i33 : Core probe non function or not plugged
Cooking stops
To continue cooking connect a probe or switch to timer mode.
E46 : Electronic communication fault (Bus RS485)
Cooking stops
Possible to launch safe mode: convection mode at 175°C (see
guidance and info about the control screen).
E53
:
Motor short-circuit or ventilation non function
Cooking stops
Switch the oven off and call a service technician.
E61 : Ambient probe short circuit
Cooking stops
Switch the oven off and call a service technician.
E62 : Ambient probe non function
Cooking stops
Switch the oven off and call a service technician.
E67 : Gas safety activated
Cooking stops
Check gas inlet. Switch the oven off and call a service technician.
E68 : Cavity at +290°C
Cooking stops
Switch the oven off and call a service technician.
E72 : Electronics at over + 75°C
Cooking stops
Switch the oven off and call a service technician.
i81 : Water flow rate too low
Cooking continues.
A cleaning cycle stops (Paused)
Check the valve and water pressure.
Switch the oven off and call a service technician.
E82 : Solenoid sticking
Cooking continues.
Switch the oven off and call a service technician.
USB stick full
USB stick is full.
Clear the USB stick
USB missing
USB stick required
Connect a USB stick
20 RECOMMENDED AND FRONT LINE SPARE PARTS
Designation
Codes
1 way 1 x 10 L/min solenoid valve
144937
Drive shaft wear ring
145587
2 way solenoid valve, 2 x 10 L/min
147152
Motorised drain outlet
148187
Sub assembly - Gas valve without safety enclosure
148222
Starting electrode
148223
After sales kit 9kW element 340 dia + seal
148752
After sales kit 15kW element 500 dia + seal
148753
After sales kit 9kW element 430 dia + seal
148754
Reed switch
300676
Three-pole 25A 230V 50/60 Hz contactor / Three-pole 32A 230V 50/60 Hz contactor
300697 / 300698
Three-pole 40A 230V 50/60 Hz contactor / Three-pole 50A 230V 50/60 Hz contactor
300699 / 300700
Tree-pole 80A 230V 50/60 HZ contactor
300702
Anti-interference relay
300769
Ultra fast fuse 0.2A 250V 5 x 20
300787
10amp 5 x 20 fuse
300788
2 point PT 100 regulating sensor
301471
1 point regulation probe, PT 100
301485
Axial fan
304194
Condensator 5 µF for pump
304269
Pump with cylinder blocks 230V 50/60HZ
304275
LN2 fixed centrifugal fan 7000rpm
304276
Motor
304292
Condenser 12.5µf
304293
Reducing gear with center return spring, 85 degrees
305108
3 phase 125A fuse holder / 3 phase 50A fuse holder
307468 / 307469
14 x 51 32A GG fuse / 22 x 58 63A GG fuse
307471 / 307472
Switching regulator 15V 15W RS 15-15
308350
Fuse 3.15 Amps
309407
Inter card cable / Inter card cable (2 metres long)
309581 / 309614
FastPAD 2 max power assembly
309635
VISIOPAD screen card
309636
LED strip
309638
VISIOPAD coder
309644
FastPAD 2 screen / FastPAD 2 Max UL relay connection
309646 / 309663
Safety box 577DBC
310324
Motorised valve 1" 230V 50/60 Hz female
314360
Pump 220/240V 50HZ
314373
FHKUC flow meter
314381
Heating e immersion heater gasket
366461
Door stop
366572
Synthetic filter
386087