AHD-WNL Monitoring & Control with iPad
®
Integration
Operation
74
V1
8.4 Administration Pages
On AHD-WNL
’s administration pages, you can configure basic set-
tings and view and export logged data, events, and alarms.
8.4.1 Launching the Administration Pages
Requirements
You need a PC or laptop and a network connection to AHD-WNL.
Procedure
Proceed as follows:
1.
Connect the PC to the industrial PC’s LAN2 port with the
Ethernet cable.
2. Launch a web browser.
3.
Enter the following address into the browser’s address bar:
This address is valid on delivery, and it can be changed on
the administration pages (see Chapter 8.4.5).
TIP!
The IP address of the separate PC’s LAN port used
must match the one of AHD-WNL. When
AHD-WNL is delivered, this must be an IP address
in the network 192.168.1.0 with the subnet mask
255.255.255.0. It may not be the same as that of
AHD-WNL, e.g. 192.168.123 oder 192.168.1.201.
4. The start page of the AHD-WNL administration is
launched: