15.3.9
Application warning mask
The Application Warning mask signals via a digital signal if an afore configured warn-
ing applies. The configuration of the Application Warning mask is carried out via
Cre-
ate Appl. Warning Mask
626.
As soon as limit switches are reached or contouring error limits are exceeded, a
warning can be issued. The warnings refer to the parameter values set in er-
ror/warning behavior. Depending on the application, any number of warnings can be
configured. This enables internal and/or external control using a common output
signal. The display of
Warning Application
273 is not affected by the Warning mask.
Create Appl. Warning Mask
626
Function
0 - no change
The configured warning mask is not changed.
2 - Activate all Warnings
The warnings reports stated are linked in the
warning mask.
10 - Warning V-belt
The
Operation mode
581 for V-belt monitoring
signals no-load operation of the application.
11 - Warning pos. SW-Limit-
Switch
1)
Warning message indicating that the positive
SW limit switch has been reached (parameter
Positive SW limit switch
1145).
12 - Warning neg. SW-Limit-
Switch
1)
Warning message indicating that the negative
SW limit switch has been reached (parameter
Negative SW limit switch
1146).
13 - Warning pos. HW-Limit-
Switch
1)
Warning message indicating that the positive
HW limit switch has been reached.
14 - Warning neg. HW-Limit-
Switch
1)
Warning message indicating that the negative
HW limit switch has been reached.
15 - Warning Contouring Error
1)
Warning message, indicating that the contour-
ing error monitoring range adjusted with pa-
rameter
Warning Threshold
1105 has been
left.
16 - Warning Encoder
An encoder with data track can trigger a warn-
ing. Selection is not effective with encoders
without data track.
17 - Warning User 1
The signal set on digital input
User Warning 1
1363 is active.
18 - Warning User 2
The signal set on digital input
User Warning 2
1364 is active.
102 - Deactivate all Warnings
All warnings are deactivated.
110 - Deactivate Warning V-Belt
Warning 10 is deactivated.
111 - Deactivate Warning pos.
SW-Limit-Switch
Warning 11 is deactivated.
112 - Deactivate Warning neg.
SW-Limit-Switch
Warning 12 is deactivated.
113 - Deactivate Warning pos.
HW-Limit-Switch
Warning 13 is deactivated.
114 - Deactivate Warning neg.
HW-Limit-Switch
Warning 14 is deactivated.
115 - Deactivate Warning Contour-
ing Error
Warning 15 is deactivated.
116 - Deactivate Warning Encoder Warning 16 is deactivated.
117 - Deactivate Warning User 1
Warning 17 is deactivated.
118 - Deactivate Warning User 2
Warning 18 is deactivated.
1)
Refer to the application manual “Positioning” for further details.
190
Operating Instructions ACU
06/13