10
3PCLIOBILBO-02
PROBLEMS AND SOLUTIONS
Displaying Special Statuses
The corresponding heater display alternates between two characters depending on the status.
Event
Heater
status
Start
conditions
End
conditions
Action
Heater
Display
fore
(1 sec.)
Heater
Display
back
(1 sec.)
Priority
Power increment
not allowed (only
for ECO models)
On/Off
Asked Cooktop
power >
Cooktop ECO
power limit
2 sec
--------
'r'
'r'
1
Heater without
pan
On
No pan or not
suitable pan
over the heater
Heater Off
In 1 minute Heater
off
'Power'
'u'
2
Heater over
temperature
Off
Heater
Temperature >
90ºC
Heater
Temperature <
80ºC
---------
' ' o 'H'
'C'
3
Heater over
temperature
On
No power is
delivered to the
heater
'Power'
Induction
generator over
temperature
Off
Heat sink
Temperature >
90ºC
Heat sink
Temperature <
80ºC
---------
' ' o 'H'
'c'
4
Induction
generator over
temperature
On
No power is
delivered to the
heater
'Power'
Heater with
residual heat
Off
Heater
Temperature >
50ºC
Heater
Temperature <
40ºC
---------
'H'
'H'
5
PROBLEMS AND SOLUTIONS
Errors/Alarms
The corresponding heater display alternates between two characters depending on the Error.
F
7
Appliance errors
Event
(Visualization Priority
Order)
Description
Action
End
All Heater Displays
(fore 0.5 sec.
back 0.5 sec)
FalloSw
Software Error
App Off (*)
--------
F0
FalloKeyOnOffEmitter
Safety Key Error
App Off (*)
--------
FA
FalloKeyOnOffReceiver
Safety Key Error
App Off (*)
--------
FC
FalloNtcShort
Touch NTc Error
App Off (*)
--------
FE
FalloNtcOpen
Touch NTc Error
App Off (*)
---------
Ft
FalloOverTemp
Touch NTc Error
App Off (*)
T < 90°C
Fc
FalloEepromChecksum
Eeprom Checksum
Error
App Off (*)
--------
FH
FalloAdc
Security Key Error
App Off (*)
--------
FJ
FalloAmbientLight
Keyboard Error
App Off (*)
Light
Condition
FL
FalloDivisor
Security Key Error
App Off (*)
--------
FU
(*) All heaters switched Off and locked