ECHO-5
Ultrasonic Motion Detector
INSTRUCTION MANUAL
GENERAL
The Echo-5 Volumetric Ultrasonic Motion Detector (hereinafter referred to as
the detector) detects an intruder’s movement in the protection area sending an
intruder alarm to a central monitoring station, or to a message sending system,
or to a control indicating equipment by opening the alarm loop using contacts
of the detector’s executive relay.
The detector forms a continuous volumetric detection area in the protected
premises.
The detector provides:
- Three-color light indication of operating modes and interferences;
- Selecting indication modes depending on protection tactics assigned for the
premises (automatically restored or selected alarm indication, alarm memory
feature);
- Disabling alarm indication as well as indication of noise/interference and
motion in protected premises (to provide operating the detector in hide
mode) with enabling indication of detector’s powering on, troubles, power
decreasing, and alarm memory;
- Discrete (four-stage) sensitivity adjustment;
- Using several detectors of this type (spaced at distances at least 5 meters
away from each other) in the same protected premises due to quartz-crystal
control of working frequency;
- Automatic self-diagnostics and testing operability of acoustic transducer,
anti-sabotage protection, monitoring jamming environment in the protected
premises, power voltage monitoring;
- Protection against unauthorized opening the detector’s case (messages about
tampering are generated by opening tamper switch contacts).
The detector is designed for round-the-clock operation.
SPECIFICATIONS
1.
The maximum volume of a protected area covered by a single detector:
250 square meters (10 m
×
5 m
×
5 m).
2.
The detector provides detecting radial movement of standard target toward
to the detector with any speed within the range of 0.3 m/s to 2 m/s.
3.
The detector is to be powered from a dc power supply with rating voltage
of 12 V with effective ripple voltage no more than 100 mV.
4.
Maximum switching current of the executive relay: 30 milliamperes at 72 V
max.
5.
Maximum detection range: at least 10 m.
6.
Pre-operation time: 10 s max.
7.
Consumed current:
- in the quiescent mode: 25 milliamperes max;
- in the alarm mode: 20 milliamperes max.
8.
Operating temperatures:
−
10 to +50°
С
.
9.
The detectors design provides:
a) Ingress protection rating: IP30;
b) Deflecting the detector case from the position in which its front panel is
parallel to the supporting surface at an angle of not less than 30 degrees in
any direction.
10.
Overall dimensions: 150 mm
×
45 mm
×
25 mm max (without the bracket).
11.
Weight: 75 g max.
INDICATION AND OPERATION
Three status LEDs of the Echo-5 indicate its operation states as shown in Table 1.
Table 1
Event/Status
Indicator’s Behavior
DIP Switch
Positions
Green
Red
Yellow
Power On
Any
Quiescent Mode
Any
Alarm
Switch 4: ON
Alarm Memory
Switch 3: ON
Trouble
Any
Undervoltage
Any
Tampering
Any
Noise/Interference
Switch 4: ON
Motion
Switch 4: ON
– Is lit steady for three seconds
– Off
– Flashes each two seconds during 30 minutes
– Flashes periodically while the signal exists (exceeds the pre-set threshold)
After detector’s power has been switched on, the detector is entering the quiescent
mode opening its
ТРЕВ
contacts for 3 s (the Power On status) and indicating this
state, as shown in Table 1. After having entered the quiescent mode the contacts of
the executive relay close while the LEDs shut off provided that no faults and
interferences have been occurred.
If a hardware failure has been occurred or some willful acts have been taken to
disturb normal operation of the detector (screening the detector’s faceplate by any
sound proof material or damaging transducers), the detector generates a trouble
message opening
ТРЕВ
contacts for 30 minutes and indicating this status as shown in
Table 1.
If the power voltage has dropped below (8.0
±
0.5) V, the detector generates an
Undervoltage message by opening
ТРЕВ
contacts for 30 minutes and indicates this
state as shown in Table 1.
A Noise/Interference status is indicated as shown in Table 1 in case of en external
noise in the protected area.
A Motion status is indicated as shown in Table 1 when a moving entity (a person or a
large thing) is detected.
The detector generates an Alarm message by opening
ТРЕВ
contacts for 3 s and
indicates this state as shown in Table 1 if the alarm indication is enabled (DIP switch
4 is set to ON).
Indication of Alarm Memory is performed as shown in Table 1 since five minutes
after generating the alarm message if DIP switch 3 is set to ON.
Indication of noise, motion and alarms is enabled only if DIP switch 4 is set to ON.
If there are several statuses to be indicated simultaneously, then alarm memory,
troubles and undervoltage messages are indicated one-by-one. When trouble and
undervoltage messages are being generated, noise/interference and motion indication
is not performed.
When the detector’s cover is open, the detector generates a Tampering message by
opening its
ВСКР
contacts which are coupled with the in-built tamper switch.
STANDARD DELIVERY
Find the following unpacking the Echo-5:
−
Echo-5 Ultrasonic Motion Detector:
1 pc.
−
Bracket:
1 pc.
−
This Instruction Manual:
1 pc.
−
Cross Recessed Round Head Thread Cutting Screw 3×8.01.016:
1 pc.
−
Slotted Countersunk Flat Head Thread Cutting Screw 3×10.01.016:
2 pcs.
−
Slotted Round Head Thread Cutting Screw 3×20.01.016:
1 pc.
−
Countersunk Flat Head Tapping Screw 3×25.016:
2 pcs.
−
Wall Plug:
2 pcs.