background image

ECHO-5 

Ultrasonic Motion Detector 

 

INSTRUCTION MANUAL

 

 

GENERAL 

The Echo-5 Volumetric Ultrasonic Motion Detector (hereinafter referred to as 
the detector) detects an intruder’s movement in the protection area sending an 
intruder alarm to a central monitoring station, or to a message sending system, 
or to a control indicating equipment by opening the alarm loop using contacts 
of the detector’s executive relay. 

The  detector  forms  a  continuous  volumetric  detection  area  in  the  protected 
premises. 

The detector provides: 

-  Three-color light indication of operating modes and interferences; 

-  Selecting indication  modes depending  on  protection tactics assigned  for  the 

premises (automatically restored or selected alarm indication, alarm memory 
feature); 

-  Disabling  alarm  indication  as  well  as  indication  of  noise/interference  and 

motion  in  protected  premises  (to  provide  operating  the  detector  in  hide 
mode)  with  enabling  indication  of  detector’s  powering  on,  troubles,  power 
decreasing, and alarm memory; 

-  Discrete (four-stage) sensitivity adjustment; 

-  Using several detectors of this type (spaced at distances at least 5 meters 

away from each other) in the same protected premises due to quartz-crystal 
control of working frequency; 

-  Automatic  self-diagnostics  and  testing  operability  of  acoustic  transducer, 

anti-sabotage  protection,  monitoring  jamming  environment  in  the  protected 
premises, power voltage monitoring; 

-  Protection against unauthorized opening the detector’s case (messages about 

tampering are generated by opening tamper switch contacts). 

The detector is designed for round-the-clock operation. 

SPECIFICATIONS 

1.

 

The  maximum  volume  of  a  protected  area  covered  by  a  single  detector: 
250 square meters (10 m 

×

 5 m 

×

 5 m). 

2.

 

The detector provides detecting radial movement of standard target toward 
to the detector with any speed within the range of 0.3 m/s to 2 m/s. 

3.

 

The detector is to be powered from a dc power supply  with rating voltage 
of 12 V with effective ripple voltage no more than 100 mV. 

4.

 

Maximum switching current of the executive relay: 30 milliamperes at 72 V 
max. 

5.

 

Maximum detection range: at least 10 m. 

6.

 

Pre-operation time: 10 s max. 

7.

 

Consumed current: 

- in the quiescent mode: 25 milliamperes max; 

- in the alarm mode: 20 milliamperes max. 

8.

 

Operating temperatures: 

 10 to +50°

С

9.

 

The detectors design provides: 

a) Ingress protection rating: IP30; 

b) Deflecting the detector case from the position in which its front panel is 

parallel to the supporting surface at an angle of not less than 30 degrees in 

any direction. 

10.

 

Overall dimensions: 150 mm 

×

 45 mm 

×

 25 mm max (without the bracket). 

11.

 

Weight: 75 g max. 

 
 
 

INDICATION AND OPERATION 

Three status LEDs of the Echo-5 indicate its operation states as shown in Table 1.

 

Table 1 

Event/Status 

Indicator’s Behavior 

DIP Switch 

Positions 

Green 

Red 

Yellow 

Power On 

 

 

 

Any 

Quiescent Mode 

 

 

 

Any 

Alarm 

 

 

 

Switch 4: ON 

Alarm Memory 

 

 

 

Switch 3: ON 

Trouble 

 

 

 

Any 

Undervoltage 

 

 

 

Any 

Tampering 

 

 

 

Any 

Noise/Interference 

 

 

 

Switch 4: ON 

Motion 

 

 

 

Switch 4: ON 

 – Is lit steady for three seconds 

 – Off 

 – Flashes each two seconds during 30 minutes 

 – Flashes periodically while the signal exists (exceeds the pre-set threshold)

 

After  detector’s  power  has  been  switched  on,  the  detector  is  entering  the  quiescent 
mode  opening  its 

ТРЕВ

  contacts  for  3 s  (the  Power  On  status)  and  indicating  this 

state,  as  shown  in  Table 1.  After  having  entered  the  quiescent  mode  the  contacts  of 
the  executive  relay  close  while  the  LEDs  shut  off  provided  that  no  faults  and 
interferences have been occurred. 

If  a  hardware  failure  has  been  occurred  or  some  willful  acts  have  been  taken  to 
disturb  normal  operation  of  the  detector  (screening  the  detector’s  faceplate  by  any 
sound  proof  material  or  damaging  transducers),  the  detector  generates  a  trouble 
message opening 

ТРЕВ

 contacts for 30 minutes and indicating this status as shown in 

Table 1. 

If  the  power  voltage  has  dropped  below  (8.0 

±

 0.5) V,  the  detector  generates  an 

Undervoltage  message  by  opening 

ТРЕВ

  contacts  for  30 minutes  and  indicates  this 

state as shown in Table 1. 

A  Noise/Interference  status  is  indicated  as  shown  in  Table 1  in  case  of  en  external 
noise in the protected area. 

A Motion status is indicated as shown in Table 1 when a moving entity (a person or a 
large thing) is detected. 

The  detector  generates  an  Alarm  message  by  opening 

ТРЕВ

  contacts  for  3 s  and 

indicates this state as shown in Table 1 if the alarm indication is enabled (DIP switch 
4 is set to ON). 

Indication  of  Alarm  Memory  is  performed  as  shown  in  Table 1  since  five  minutes 
after generating the alarm message if DIP switch 3 is set to ON. 

Indication of noise, motion and alarms is enabled only if DIP switch 4 is set to ON. 

If  there  are  several  statuses  to  be  indicated  simultaneously,  then  alarm  memory, 
troubles  and  undervoltage  messages  are  indicated  one-by-one.  When  trouble  and 
undervoltage messages are being generated, noise/interference and motion indication 
is not performed. 

When  the  detector’s  cover  is  open,  the  detector  generates  a  Tampering  message  by 
opening its 

ВСКР

 contacts which are coupled with the in-built tamper switch. 

STANDARD DELIVERY 

Find the following unpacking the Echo-5: 

 

Echo-5 Ultrasonic Motion Detector: 

1 pc. 

 

Bracket: 

1 pc.

 

 

This Instruction Manual: 

1 pc.

 

 

Cross Recessed Round Head Thread Cutting Screw 3×8.01.016: 

1 pc.

 

 

Slotted Countersunk Flat Head Thread Cutting Screw 3×10.01.016: 

2 pcs.

 

 

Slotted Round Head Thread Cutting Screw 3×20.01.016: 

1 pc.

 

 

Countersunk Flat Head Tapping Screw 3×25.016: 

2 pcs.

 

 

Wall Plug: 

2 pcs.

 