GENERAL 

S2000-PIK Addressable Ceiling Mount Volumetric Passive Infrared (PIR) Motion Detector (hereinafter referred to as the 

detector)  is  designed  to  be  used  indoors  (within  shops,  offices,  museums,  apartments,  etc.).  It  detects  intrusion  into 

protected  areas  and  sends  an  alarm  message  to  the  connected  S2000-KDL  controller  via  the  two-wire  multiplex 

addressable polling loop. 

The detector is intended to work as a part of an Orion Integrated Security System. 

The detector provides increased immunity against lighting and radio frequency interference. 

KEY FEATURES 

  Ceiling Mounted 

  Employs two dual-element pyro-electric infrared sensors 

  The  special  lens  provides  the  volumetric  detection  zone  with  high-density  coverage  offering  high  probability  of 

detecting an intruder in every direction 

  Protected against insects entering to the pyro-electric infrared sensors 

  Microcontroller signal processing 

  Powered via the multiplex addressable polling loop of the S2000-KDL 

  Supports DPLS_v2.xx protocol 

SPECIFICATIONS 

Detection Range 

Coverage diameter of 9 m at 5 m mounting height 

Detection Area 

Volumetric, cone-type, 10 far/ 1 mid/ 1 near zones 

Optics 

Fresnel lens 

Input Voltage (from a S2000-KDL) 

8 ÷ 10 VDC 

Current Consumption (via the loop of the S2000-KDL) 

0.5 mA max when indication is off 

Operating Temperatures 

30 to +50°C 

Humidity 

95% at 25°C, non-condensing 

Overall Dimensions (diameter x height) 

105 

×

 45 mm max 

Weight 

0.1 kg max 

MOUNTING LOCATION CONSIDERATIONS 

Considering a location to mount the detector, please take 
into account that the detection zone must not be obscured 
by  curtains,  curtain  tracks,  door  moulding,  glass 
partitions, etc. 

Do  not  locate  the  detector  where  it  can  be  exposed  to 
false  alarm  sources  such  as:  air  conditioners,  heaters, 
radiators, etc. 

The maximum mounting height is 5 meters. 

Wires of the multiplex addressable polling loop should be 
located away from high-voltage electric cables. 

The view of the detection area is shown in Figure 1. 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1: Detection Area

 

10 m 

9 m 

5 m 

Summary of Contents for S2000-PIK

Page 1: ...d sensors Microcontroller signal processing Powered via the multiplex addressable polling loop of the S2000 KDL Supports DPLS_v2 xx protocol SPECIFICATIONS Detection Range Coverage diameter of 9 m at 5 m mounting height Detection Area Volumetric cone type 10 far 1 mid 1 near zones Optics Fresnel lens Input Voltage from a S2000 KDL 8 10 VDC Current Consumption via the loop of the S2000 KDL 0 5 mA m...

Page 2: ...able loop of the S2000 KDL controller it must be assigned to a unique number 1 to 127 within the loop the address which is stored in the S2000 PIK non volatile memory This address provides identifying the detector by the S2000 KDL controller Moreover the monitoring strategy must be defined which will be used by the S2000 KDL controller while processing signals received from the S2000 PIK Programmi...

Page 3: ...of 0 5 m s to 1 m s The detector should issue an alarm and its LED should flash Wait until the LED finishes flashing and then begin crossing the detection pattern from another side The detector should issue an alarm If nobody is moving within the detection pattern no alarms should be issued ENABLING DISABLING LED INDICATION LED indication can be controlled either via a PC or by means of the detect...

Page 4: ...tability must be brought within 12 months from date of original purchase In no case shall seller be liable to anyone for any consequential or incidental damages for breach of this or any other warranty express or implied or upon any other basis of liability whatsoever even if the loss or damage is caused by the seller s own negligence or fault Some countries do not allow limitation on how long an ...

Reviews: