Specifications

11

Output Level

Balanced:

Sele4, -

1

0, -50 dBµ (typical when meter reads “0”)

Unbalanced:

0 dBµ (typical when meter reads “0”)

Max. Output Level

Balanced:

+

1

8 dBµ

Unbalanced:

+20 dBµ

Frequency Response:

+/- 

1

dB (20 Hz to 20 kHz)

Distortion:

0.0

1

(@ +

1

8 dBµ THD+N, 20 Hz to 20 kHz BW Limited)

Signal-to-Noise

Fundamental:

-99 dB*

w/ AUX MAX

1

R Module:

-94 dB*

w/ MIC2X Module:

-64 dB*

w/ TEL

1

S Module:

-92 dB*

Tone Controls

Bass Frequency:

1

00 Hz (+/- 

1

0 dB minimum)

Treble Frequency:

1

0 kHz (+/- 

1

0 dB minimum)

Low Cut Frequency:

1

25 Hz @ -6 dB/octave

Signal / Clip Indicator

Signal Detect Threshold:

1

0 mV @ output of module

Signal Indicator Hold Time:

50 mS (green indicator)

Clip Detect Threshold:

6V @ output of module

Clip Detect Hold Time:

50 mS (red indicator)

Output Impedance

Balanced:

50 ohms @ +4 dBµ, 600 ohms @ -

1

0 dBµ, 5 ohms @ -50 dBµ

Unbalanced:

1

00 ohms

Power Consumption:

2

1

watts

AC Power Receptacle:

500 watts maximum power, unswitched

Dimensions:

1

7-

1

/4" W x 3-7/8" H x 

1

4-3/4" D

Product Weight:

1

5 lb.

Safety Approvals:

Listed to UL Standard 60065 for U.S. and Canada

* Referenced to max output level, 20 Hz to 20 kHz bandwidth limited.
All specifications subject to change without notice.

Summary of Contents for VMIX

Page 1: ...Power Vector Mixer Model VMIX Installation and Use Manual 2005 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 2134 01C 1204 ...

Page 2: ...y If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused fo...

Page 3: ...Balanced Output 6 Remote Volume Control 6 Bridging 6 Mute Control 7 System Expansion of Power Vector Mixers 7 OPERATION 8 9 Front Panel Controls Indicators 8 Input Volume Controls and Signal Clip Indicator 8 Bass and Treble Controls 8 Master Volume Control 8 Average Peak Switch LED Output Meter 8 Power Switch Power Indicator 8 Rear Panel Controls 9 Balanced Out Switch 9 Other Controls 9 Tone Contr...

Page 4: ...reble Control Controls the amount of cut or boost of treble frequencies above 10 kHz 4 LED Output Meter An 11 segment LED output level meter monitors the output level of the mixer 5 Master Volume Control Controls overall level of mixed input signals 6 Power Indicator An LED indicates AC power status 7 Bass Control Controls the amount of cut or boost of bass frequencies below 100 Hz 8 Average Peak ...

Page 5: ...e bay 6 that allows roll off of frequencies below 125 Hz 6 Tone Control Bypass Switch A slide switch located in module bay 6 that allows the effects of the bass and treble controls to be bypassed 7 AC Line Cord and Circuit Breaker A grounded 3 wire AC line cord provides power to the mixer and is protected by a resettable circuit breaker 8 Balanced Out Level Switch Three position slide switch that ...

Page 6: ...e Installation Eight module bays are available to accept Bogen s new advanced input modules Module bays 7 8 can also accommodate Bogen s new advanced output modules thereby allowing users to customize the mixer to suit the needs of the installation The bays will not accept Bogen s older style plug in modules Before installing a module read the instructions included with the module and make the des...

Page 7: ...included so that the input function of the module bay is not lost when an output module is installed Input Modules Functionality The Power Vector mixer accepts Bogen s new advanced input modules which provide a wide range of input types allowing the mixer inputs to be custom configured in both type and number for a particular application Input modules can be installed into any of the 8 module bays...

Page 8: ...l of the MasterVolume control The impedance of the shorting connections must be less than 100 ohms in order to operate the control The Bogen Remote Volume Control Panel Model RVCP provides a simple and elegant means of remote control Alternatively a SPDT spring loaded center off switch or two SPST push button switches can provide the necessary contacts for remote control Bridging This connector ma...

Page 9: ...rol lines it is possible to connect two or more Power Vector units into a larger integrated system Wire the bridging jack and mute control lines as shown in the diagrams for bridging either 2 or 3 units together The overall system gain of PowerVector products dimin ishes when they are bridged because each unit s mix bus loads down the other product s bus When bridging two PowerVector products the ...

Page 10: ...e The bass control has a cut boost range of 10 dB at frequencies below 100 Hz Master Volume Control The overall volume level of the mixer is set by a MasterVolume control The MasterVolume control is motorized and can be controlled by man ually adjusting the knob or by a remotely mounted control station Connections and requirements for the remote control station are described in the Connections sec...

Page 11: ... andTreble controls is located on the back plane of module bay 6 It is sometimes desirable to bypass the tone controls when other forms of system equalization are used A screwdriver can be used to set the switch The switch must be set before a module is installed in this bay Low Cut Switch The Power Vector mixer provides a low cut filter that rolls off frequen cies below 125 Hz The slide switch fo...

Page 12: ...Block Diagram 10 ...

Page 13: ... minimum Low Cut Frequency 125 Hz 6 dB octave Signal Clip Indicator Signal Detect Threshold 10 mV output of module Signal Indicator Hold Time 50 mS green indicator Clip Detect Threshold 6V output of module Clip Detect Hold Time 50 mS red indicator Output Impedance Balanced 50 ohms 4 dBµ 600 ohms 10 dBµ 5 ohms 50 dBµ Unbalanced 100 ohms Power Consumption 21 watts AC Power Receptacle 500 watts maxim...

Page 14: ...eration of motorized master volume control Fits in standard single gang electrical box Decora style cover plate PVSC Power Vector Security Cover Prevents tampering with system settings Power and meter switches accessible Simple installation PVMC Power Vector Module Cover Prevents tampering with module controls Adaptable for different module types Covers unused module slots A variety of accessories...

Page 15: ... PARTICULAR PURPOSE ARE HEREBY DIS CLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NO...

Page 16: ...50 Spring Street Ramsey NJ 07446 U S A Tel 201 934 8500 Fax 201 934 9832 www bogen com ...

Reviews: