Bogen RIO1S Installation Manual Download Page 1

RIO

1

S

Relay / Input / Output
Transformer-Balanced Module

Features 

Transformer-isolated, balanced line-level input

600-ohm or 

1

0k-ohm jumper-selectable input impedance

Transformer-isolated, balanced line-level output

8-ohm, 750mW output

Input and output level controls

Relay responds to selectable priority level

External control of priority muting

N.O. or N.C. relay contacts

Input can be muted from higher priority modules, with signal fade back

Output can activate with relay priority level

Screw terminal strips

RJ

11

connection with line output and dedicated N.O. relay contact

© 2007 Bogen Communications, Inc.
54-2097-0

1

F  0706

Specifications subject to change without notice.

Summary of Contents for RIO1S

Page 1: ...put and output level controls Relay responds to selectable priority level External control of priority muting N O or N C relay contacts Input can be muted from higher priority modules with signal fade back Output can activate with relay priority level Screw terminal strips RJ11 connection with line output and dedicated N O relay contact 2007 Bogen Communications Inc 54 2097 01F 0706 Specifications...

Page 2: ... rails Make sure that both the top and bottom guides are engaged 5 Push the module into the bay until the faceplate contacts the unit s chassis 6 Use the two screws included to secure the module to the unit WARNING Turn off power to unit and make all jumper selections before installing module in unit Note This module may include a break away tab as pictured below If present remove this tab to inst...

Page 3: ...rfacing to paging systems with override capabilities PCM2000 ZPM3 Signal Output Transformer balanced low imped ance 8 ohm line level output Input Signal Transformer balanced line level input Mute Mute Provides access to the mute bus priority system Allows external equipment to directly control the internal mute buses Prioritized Relay Output Provides access to the priority controlled relay contact...

Page 4: ...nuously Input Bus Assignment This module can be set to operate so that the input signal can be sent to the main unit s A bus B bus or both buses Bus selection pertains to M Class use only PowerVector has only one bus Set jumpers to Both for Power Vector use External Mute Priority Level Determines what priority level the system will see when looking at the external control Selecting Level 1 will re...

Page 5: ...Gating The output signal can be available continuously or available only when the relay priority level set ting has been met or exceeded When set to ACTIVE it provides continuous signal output When set to GATE it provides output based on priority level Relay Contacts This module s screw terminal relay contacts can be set for normally open N O or normally closed N C operation Output Bus Assignment ...

Page 6: ...remaining lead to the minus ter minal of the RIO1S Note If polarity of the output signal versus the input signal is important it may be necessary to reverse input lead connections Unbalanced Connection When the external device provides only an unbalanced connection signal and ground the RIO1S module should be wired with the terminal shorted to ground The unbalanced signal s shield wire is connecte...

Page 7: ... signal is important it may be necessary to reverse input lead connections Unbalanced Connection When the external device provides only an unbalanced connection signal and ground the RIO1S module should be wired with the terminal shorted to ground The unbalanced signal s shield wire is connected to the input module s ground and the signal hot wire is connected to the terminal Since unbalanced conn...

Page 8: ...50 Spring Street Ramsey NJ 07446 U S A 201 934 8500 Fax 201 934 9832 www bogen com 1 2 3 4 5 6 Enabled Disabled Gate Relay Out Out Relay Block Diagram ...