28
input combination to play at the maximum limit (default
value is 25, full volume). This will normally be quite loud.
Be careful that people are not next to speakers and that the
power rating of the speakers is high enough to handle full
amplifier power.
Note
: The system should be completely wired before making
any of these adjustments, since the installer will normally want
to listen to the output in order to make the adjustment.
1.
Enter programming mode and press the NEXT or BACK buttons until
VOL LIMIT appears on the display.
2.
Press ENT to enter the function.
3.
Select the amplifier and input you wish to limit by pressing its selector
buttons. The display shows the current amp-input and its current vol-
ume limit setting. The 2-digit volume level can range between 00 and
25. The factory default is 25, allowing full volume. Subsequently, the
display will show the current setting.
5.
Press the arrow buttons to increase or decrease the volume. The level
number will increase or decrease, and the pointer will move left or right
in response to the changes made.
Note:
Press and hold arrow
buttons to effect rapid
changes in volume. Quick
presses of the buttons will
effect single-step changes in
volume.
6.
Once you have set the desired
limit for an input, press ENT
. The PROG light will blink to indicate that
data was stored.
Programming
7.
Select another amp-input combination and repeat Steps 4 and 5 to set
other levels.
Remember to press ENT after setting each level.
8.
Once all levels are set, press EXIT to return to the function menu. At
this point you can exit the programming mode or press the NEXT/BACK
buttons to select another function.
A1/AUXA 25
5003-01.QXD 8/14/00 4:46 PM Page 32