22
Assignment
The ASSIGNMENT function lets you assign a priority levels to each amplifi-
er-input combination. This function lets you create a variety of configura-
tion schemes and obtain maximum versatility to meet application needs.
The factory default priority levels are listed below:
Input
Factory Priority Level
MIC A
1
MIC B
2
AUX A
3
1 = highest priority
AUX B
4
6 = lowest priority
AUX C
5
AUX D
6
Note:
Mic A and Mic B can only be assigned priority 1 or 2; Aux
inputs can only be assigned priority 3, 4, 5, or 6. Therefore,
mics will always have higher priority than Aux inputs.
1.
Enter programming mode and press ENT when the function title
ASSIGNMENT appears on the display.
2.
When the function is entered, the
A1 / AUX A (Amp 1 and Aux A) amp-
input combination is always shown, along with that combination’s cur-
rent priority assignment number (3). To select another combination, use
the AMP buttons and Input but-
tons. The new combination
appears on the display with its
associated priority level.
3.
A priority level can only be
assigned when it is not in use by
another input. To eliminate an
input priority so that it is available
for use by another, select the amp-
input combination that has the desired priority number. Press NEXT or
BACK until a dash (—) appears and then press ENT. This disconnects
that input from the amp so that its priority level is available for use with
the other input.
4.
Now you can select the desired amp-input combination and then press
the NEXT or BACK buttons to increment through available priority levels
(for Mics, 1 & 2; for Aux inputs, 3, 4, 5 or 6).
Programming
A1/AUXA 3