Description

The Bogen Model CA

1

9 is a momentary, rocker-type call switch

designed for use with Bogen Multicom 2000

®

Communication

Systems. The CA

1

9 will facilitate single-push call-in on the same

station and wiring as the Bogen enhanced staff stations (MCESS
or MCWESS) set to Level 4, 5, or 6. The CA

1

9 requires just two

conductors back to the system head-end. The CA

1

9 may also be

used for staff stations set to Levels 

1

, 2, or 3. Any station using

the CA

1

9 must have an associated speaker.

Note

Requires special version Multicom Software V6.3 (MCPCA25W63).

Operation

When pushed once and released, the CA

1

9 will send two square

wave-pulses simulating the telephone going off-hook and on-
hook twice. This will establish a logged call into the designated
administrative station.The switch may also be used to initiate an
emergency call if pressed twice with a one-second interval
between presses.

Note

The CA

1

9 will operate only when the associated staff or enhanced

staff handset in is the on-hook position.

Caution

Observe color coding. The red wire connects to the station
annunciator point while the black wire connects to the station
ground point.

Installation

The CA

1

9 is designed for flush-mounted installation in a single-

gang box. The figure below illustrates the proper wiring
connections. Important: The shield must not be grounded at any
point other than the system head-end.

8

OHMS

CA19

PRESS

TO CALL

BLACK

RED

TO

CONSOLE

GROUND

ANNUNCIATOR

SPEAKER

SPEAKER

FIGURE - MODEL CA19, CONNECTING DIAGRAM

T 725

TRANSFORMER

ENHANCED

STAFF

STATION

JUNCTION

BOX

1/4 W

1/8 W

1/2 W

1 W

2 W

COM

4W

ROOM SPEAKER

BLU

GRN

YEL

ORN

RED

BRN

BLK

CALL-IN SWITCH

Model CA19