Operating instructions for S 40-3...S 150-3 series screw compressors
Page 43
Installation
3.5
Commissioning
Conduct trial run
1. Re-enable the mains disconnecting device.
2. Use ON button on compressor control to switch on compressor.
Æ
Compressor starts operating.
Æ
When the factory-set switch-off pressure is reached, the compressor
cuts off automatically.
3. Check network pressure on control display.
4. If necessary, reset operating pressure (pressure target value).
Æ
The compressor is ready for operation.
Æ
For control function see control display.
5. Switch off compressor after several hours of trial operation under maximum
working load.
Record the test results in the commissioning certificate.
Commissioning follow-
ing extended stoppages
If an extended stoppage is scheduled, you should contact BOGE's service
department beforehand.
Following an extended stoppage of more than 2 months, fill a small amount of
oil into the suction controller prior to starting the compressor!
Fig. 3.6: Suction controller
WARNING!
Only fill the suction controller with the grade of oil used to operate the com-
pressor.
Never mix different grades or brands of oil.
WARNING: Risk of injury!
Press the emergency stop button, disconnect the power supply using the
mains disconnection device and affix a padlock to prevent it from being
switched on again unintentionally.
1. Unscrew the plug from the
suction controller (1).