BOGE FOCUS compressor control for piston compressors
Page 21
FOCUS
1.5
Grouped parameters / parameter management
1.5 Grouped parameters / parameter management
Servicing interval
If the
Code 00111
is entered, a display for the servicing intervals is opened.
The servicing intervals fort he compressor, the motor and the receiver are set
here. If a dryer module is connected the servicing interval for the dryer can be
set here as well.
By means of the
INFO key
this setting can be left without saving the chang-
es or the counter reading.
The display of the servicing intervals can also be left by means of the
INFO
key
. With the setting of 2.000.000 receiver load cycles this down counter
is deactivated.
Parameter factory
setting
In case somebody has changed any parameters and wants to recover a func-
tionally safe status the factory setting resp. commissioning setting can be re-
stored.
To do this the compressor must be in the OFF status. Only then the
Code
00988
can be entered.
In the displayed window you can read: Restore settings? – and you can select
either Yes or No.
Should the saved parameters be restored, you can use the
/
keys
to se-
lect Yes and acknowledge by means of the
ENTER key
.
Now the current data on the basic module are overwritten with the factory-set
values.
Base load switch control
As of version 1.11 setting of the base load switch control (BLS) is effected by
Parameter P070 „Number of compressors" and P071 „Interval time base load
switching", see also
„ Base load switch control with additional compressors“,
page 25.
As of version 1.18 parameters P075 to P078 (
p
max
and
p
min
of BLS pressure
ranges 1 and 2) are added. These parameters regulate the output release of
the base load switch control via pressure measurement.
The servicing intervals for compressor, motor and dryer are specified in hours,
fort he receiver the load cycles of the internal receiver are counted (One cycle
consists of 1 x output and 1 x no output each).
With the
/
keys
the corresponding servicing interval is selected and ac-
knowledged by means of the
ENTER key
. Now the digit starts blinking and
can be changed using the
/
keys
. Only after having acknowledged and
entered the value by means of the
ENTER key
the new servicing interval
is accepted and the corresponding down counter restarted.