BOGE Operating instructions for scroll compressors, series EO 6...EO 22 D
Page 65
Servicing and maintenance
6.3
Having maintenance work performed at fixed servicing intervals
6.3 Having maintenance work performed at fixed
servicing intervals
Every 3,000 operating
hours: Changing the
suction filter cartridge
Change the suction filter cartridge:
–
If damaged.
–
After it has been cleaned twice.
–
Depending on soiling, also after 3,000 operating hours or annually at serv-
icing intervals.
Changing the filter cartridge
1. Switch off the compressor using the OFF button.
5. Remove the old filter cartridge (see “Removing the filter cartridge” on
6. Insert the new filter cartridge (see “Fitting the filter cartridge” on page 61).
Every 3,000 operating
hours / annually:
Function check of the
safety valves
WARNING
Risk of injury due to sharp edges, hot surfaces, overpressure and
exposure to dust!
This maintenance work should only be carried out by authorised and quali-
fied personnel.
Î
Wear PPE.
Prior to the maintenance work:
2. Open the mains disconnecting device and secure it to prevent it being
switched on again.
3. Allow all hot compressor components to cool to 50°C.
4. Depressurise the system.
WARNING
Risk of injury from flying parts caused by overpressure, e.g. pressu-
rised components bursting or detonating!
Risk of injury due to sudden discharge of hot compressed air!
It is forbidden to operate the compressor without the installed safety devices.
A safety valve prevents inadmissible overpressure.
Î
The specified final compression pressure must not be exceeded.
Î
Observe the statutory regulations applicable in the installation location
for operating safety devices against overpressure.