Servicing and maintenance
6.2
Performing maintenance work between fixed servicing intervals
Page 60
BOGE Operating instructions for scroll compressors, series EO 6...EO 22 D
6.2 Performing maintenance work between fixed
servicing intervals
Monthly: Check / replace
supply air filter for switch
cabinet ventilation
Type EO 11...EO 22 D only.
Check the function of the supply air filter mats in the switch cabinet:
–
Once per month, however at least every 500 operating hours.
–
Reduce interval if the air taken in is heavily polluted.
Replace the supply air filter mats:
–
When dirt becomes encrusted on the filter mats, or at least once a year.
Replacing the supply air filter mat on the switch cabinet
1. Switch off the compressor using the OFF button.
2. Remove the cladding, see Figure 6.1.
3. Take the filter out of the cartridge.
4. Fit the new filter.
5. Re-fit the cladding.
Monthly: checking /
cleaning the suction
filter
Clean:
–
Once per month, however at least every 500 operating hours.
–
Reduce interval if the air taken in is heavily polluted.
Change:
–
If damaged.
–
After it has been cleaned twice.
NOTE
Always keep a sufficient stock filter mats as replacements.
DANGER
Danger of death due to electric current!
Coming into contact with live parts, defective insulation or components can
be fatal.
Prior to all work on the switch cabinet:
Î
Open the mains disconnecting device and secure against accidental
switching on again using a padlock.