BOGE Operating instructions for scroll compressors, series EO 6...EO 22 D
Page 47
Commissioning
5.3
Operating the DRL 6-2 DL dryer
5.3 Operating the DRL 6-2 DL dryer
The integrated DL dryer is switched on and off via the compressed air com-
pressor.
Condensate
After a few hours of operation with compressed air flowing, it should be
checked whether condensate is accumulating and being drained.
Pressure dew point display
Fig. 5.1: Pressure dew point display
ATTENTION
Danger of property damage!
Î
Wait for approx. 5 minutes between switching the DL dryer off and on to
allow the pressure in the refrigeration system to equalise.
The pressure dew point display
shows the pressure dew point
reached by the DL dryer.
1 Blue field: pressure dew point too low
2 Green field: pressure dew point OK
3 Red field: pressure dew point too high