BOGE Operating instructions for C 16 N...C 30 N, C 16 F N...C 30 F N series screw compressors
Page 49
Maintenance
6.3
Maintenance work compressor
Spare and wearing parts
6.3 Maintenance work compressor
Cleaning or changing
suction filter
Cleaning:
–
1x monthly, however, at least every 500 operating hours.
–
Correspondingly earlier if the air taken in is heavily soiled.
Change:
–
In the event of damage.
–
After the second cleaning.
Switch off the compressor with the OFF button.
Fig. 6.2: Changing the intake filter
WARNING!
Only use original spare parts, compressor oils and operating materials re-
leased by BOGE for repair and maintenance work.
BOGE is not liable for any damage resulting from the use of other spare parts
or operating materials.
WARNING!
If the scavenge line filter is soiled the oil consumption may increase signifi-
cantly!
WARNING: Risk of injury!
Actuate emergency-stop switch/button, open mains disconnecting device
and secure by means of lock out tag out.
Removing the filter car-
tridge
–
Open safety sound insu-
lation hood.
–
Remove lid (1) of the filter
housing.
–
Take out filter insert (2).