6.2 Time output management menu
This menu can be used to view all the time outputs, modify their status
(Start/Stop), configure the DHF distribution in Init mode and configure the
“impulse” and “D1D2" distribution.
This menu allows you also to configure the impulse output (Impuls 01) to
provide TBT 24VDC (0,5A) power supply.
To go to the SIGMA time output management menu, validate the option in
the technician menu with the
key,
The following screen is displayed :
You can view the different options and
change the values using the
and
keys.
You can go through the different outputs
by validating using the
key.
The 3 outputs (Impulse 01, Afnor 02 and DHF03) are not programmable
with a time zone differential.
The placing of a DHF output in “INIT”
status is active for 4 hours before return
to START mode (The init mode display is
alternating with the normal display during this period).
This menu can be used to set the power of the DHF output with a choice of
25mW / 125mW (by default) / 500mW and assign the system address from
1 to 4 (1 by default).
18
Time out
puts ok
Func tion set ting õ
D1D2 min
ute:06s ú
START 00:00 ok
Afnor 02: START ú
ok
DHF 03 : INIT ú
125mW chan
nel:1 ok