![Bodet KELIO PRIO V2 Instructions Manual Download Page 12](http://html.mh-extra.com/html/bodet/kelio-prio-v2/kelio-prio-v2_instructions-manual_2782428012.webp)
7.3 Gateway configuration
Press '
3
' (GW) from the IP configuration menu and enter
the new gateway address using the KELIO
PRIO digital
keypad; press '
E
' to confirm (press '
C
' to correct if you
make a mistake):
Note: If the gateway is not used, the address must be "0.0.0.0".
7.4 Network test
The terminal has a menu that lets you test the network.
1. To access it, press '
2
' (TST) from the administrator menu
welcome screen:
Note: Press '
1
' (BOOT) to reboot the terminal (terminal
reset).
2. Press '
2
' (PING) and enter the destination address
of the machine to ping (the default address
127.0.0.1 corresponds to the terminal's localhost
address).
3. Press '
E
' to confirm to launch the ping on the
remote machine:
The terminal displays the following message during the
ping test:
The terminal displays the following result if the remote
machine responds to the ping:
If the remote machine does not respond to the ping, the
terminal displays the following result:
8. ADJUSTING THE DISPLAY CONTRAST
The LCD’s screen contrast can be adjusted.
The contrast adjustment is activated for a maximum of 3 seconds when the terminal boots up:
-
Press the
F1
function key to reduce the contrast,
-
Press the
F2
function key to increase the contrast.
The keys return to their main function once these 3 seconds have expired.
I P = 1
R E T = F 1
G W = 3
M A S K = 2
G W
0 1 7 . 2 4 0 . 2 4 5
1 7 2 .
T S T
B O O T = 1
P I N G = 2
P I N G
0 1 7 . 0 3 0 . 0 2 8
1 7 2 .
P I N G
P L E A S E W A I T
P I N G : 5 / 5
0 2 8
1 7 2 . 0 1 7 . 0 3 0 .
P I N G : 0 / 5
0 2 8
1 7 2 . 0 1 7 . 0 3 0 .
B I O = 3
I P = 1
R E T = F 1
T S T = 2