5.  TECHNICAL CHARACTERISTICS

 

   

118

158

79

118

79

158

Characteristics

Values 

Operating voltage................................................ 230V  50/60 Hz
Power consumption............................................. max. 30 mA
Input power.......................................................... 3W on average
External fuse recommended............................... 2A, 250V

Switching power..................................................

(external fuse required) 

250 V , 16 A (resistive load)

250 V , 3A (inductive load)

24 V

, 16 A

Surge category.................................................... Category III, 300 V 

OUT1/2/3 and power supply

Input IN4 / IN5.....................................................

Low/L logic from 0 to 1.0 V
High/H logic from 1.5 V

 to 32 V

GSM-/GPRS module frequency.......................... GSM900: 880 - 915 MHz

GSM1800: 1710 - 1785 MHz

Required cable ends........................................... OUT1/2/3: 2.5 mm²

IN4/5: 1.5 mm² 

Antenna supplied................................................. MMCX connector, cable length: 3 metres
Operating temperature........................................ -10°C to +55°C
Relative humidity................................................. 90%, not condensed
Weight................................................................. 450 g
Protection class................................................... IP40
Fastening............................................................. Wall-mounted box
Dimensions.......................................................... See above

EN

Summary of Contents for GSM CONTROL

Page 1: ...r r ception que le produit n a pas t endommag durant le transport pour r serve au transporteur BODET Time Sport 1 rue du G n ral de Gaulle 49340 TREMENTINES France Tel support France 02 41 71 72 99 Te...

Page 2: ...e product 9 1 5 1 Description of the GSM control 9 1 5 1 1 Using the Stop Reset button 10 1 5 1 2 Behaviour of the LEDs 10 1 5 2 General operation 10 2 INSTALLATION 11 2 1 Pre requisites 11 2 2 Changi...

Page 3: ...ck 16 3 3 10 Other useful commands 17 3 3 10 1 Activation deactivation of the BLOCK mode 17 3 3 10 2 Using the NEWS function 17 3 3 10 3 Viewing the contact list and details of a contact 17 3 3 10 4 C...

Page 4: ...duit 28 1 5 1 Descriptif de la commande GSM 28 1 5 1 1 Utilisation du bouton Stop Reset 29 1 5 1 2 Comportement des LEDs 29 1 5 2 Fonctionnement g n ral 29 2 INSTALLATION 30 2 1 Pr requis 30 2 2 Modif...

Page 5: ...0 Autres commandes utiles 36 3 3 10 1 Activation d sactivation du mode BLOCK 36 3 3 10 2 Utilisation de la fonction NEWS 36 3 3 10 3 Visualisation du r pertoire et d tails d un contact 36 3 3 10 4 Mod...

Page 6: ...risks or sources of danger when installing using and maintaining this product Symbol Description IEC60417 1641 Operating instructions IEC60417 5031 Direct current IEC60417 5032 Alternating current IE...

Page 7: ...external input 3 input option card of the Sigma master clock or to the control box of the stand alone Melodys lockdown pack the GSM control allows audio systems Harmonys or Melodys or Sigma Sound to...

Page 8: ...protected by an external protection system Due to the purely functional separation between the relays mixed operation between mains voltage and extra low voltage is not permitted The 3 x 230V switchin...

Page 9: ...guration See section 1 5 1 1 Using the Stop Reset Button for more information on how to use this button 8 SIM card slot Compatibility with the mini SIM format 25x15 mm 2FF only 9 Relays OUT1 OUT2 OUT3...

Page 10: ...ed Off Normal operation Continuously lit BLOCK mode activated the alarms cannot be triggered Flashes continuously GSM connection error detected PIN code Lit for 3 seconds receiving an SMS The behaviou...

Page 11: ...de when you order it 2 3 Mechanical installation 1 Drill 4 holes in a wall according to the layout and dimensions shown opposite 2 Insert the plugs into the holes 3 Open the box by unscrewing the 4 sc...

Page 12: ...4 and output OUT1 is already made at the factory on the box side For the connection of the alarm input IN5 and the 2 other outputs OUT2 and OUT3 refer to the diagram above and use the 3 pair cable sup...

Page 13: ...s a location for each stored number one of the 50 available locations within its memory For each of the 5 groups one or more functions on the product are allowed To program the product the following r...

Page 14: ...ce name max 15 characters Example newname NAMEOFSITE Name of your institution example V HUGO School 3 3 3 Allocation of rights Steps Command to be sent by SMS Description 5 RESET G1 PINcode Reset the...

Page 15: ...the SMS when the corresponding alert is activated max 10 characters Example newname Lockdown 25 SET IN5 LH 1 PINcode Configuration of the IN5 input 3 3 6 Activation and setting of the alarm Steps Com...

Page 16: ...Section 3 2 2 Contact list and Rights Management to perform the check 31 STATUS PINcode Indication of the product status at the current time for checking the configuration 32 SET PIN NEWPINCODE PINco...

Page 17: ...tion A TEST TEL PINcode Identification of the total number of phone numbers stored in memory and the number of numbers stored in each group B TEST TEL GX PINcode Identification of saved contacts name...

Page 18: ...rticularly useful for removing the contact from one group as it is linked to the number location and a contact in 2 groups will have 2 different locations without deleting it from the other group Dele...

Page 19: ...t the Administrator will receive a warning SMS alerting them of the triggering of the intrusion alarm as the alarm input IN4 is dedicated to the escalation of this alarm and all groups except G5 have...

Page 20: ...ve load 24 V 16 A Surge category Category III 300 V OUT1 2 3 and power supply Input IN4 IN5 Low L logic from 0 to 1 0 V High H logic from 1 5 V to 32 V GSM GPRS module frequency GSM900 880 915 MHz GSM...

Page 21: ...d in the device Date programmed in the device Time between 2 status changes of a relay Time between 2 alarm messages 4 SET NAME BodetGSM PINcode BodetGSM 0 48 The name was changed from GX155 to BodetG...

Page 22: ...Function disabled 13 RESET G5 PINcode BodetGSM 0 48 G5_ALARMSMS OFF G5_INCALL1 NO G5_INCALL2 NO G5_INCALL3 NO G5_NEWS OFF G5_SMSFORWARD NO Client product name Firmware version Function disabled Funct...

Page 23: ...function set Status of the incoming call function set 22 SET NAMEIN4 ALERT A PINcode BodetGSM 0 48 IN1 No Name IN2 No Name IN3 No Name IN4 ALERT A IN5 No Name OUT1 ALERT A OUT2 ALERT B OUT3 ALERT C C...

Page 24: ...mber registered Location number and group assigned to the contact 29 TEST TEL G1 PINcode BodetGSM 0 48 Grp G1 Member 01 MARTIN Client product name Firmware version Group identification List of contact...

Page 25: ...ues ou des sources de danger lors de l installation de l utilisation et de la maintenance de ce produit Symbole Description IEC60417 1641 Manuel d utilisation IEC60417 5031 Courant continu IEC60417 50...

Page 26: ...e entr e externe carte option 3 entr es de l horloge m re Sigma ou sur le bo tier bouton du pack PPMS Melodys autonome la commande GSM permet de commander des syst mes audio Harmonys ou Melodys ou Sig...

Page 27: ...une s paration uniquement fonctionnelle entre les relais une exploitation mixte entre la tension du secteur et une tr s basse tension est interdite Les 3 entr es de commutation 230V sont pr sentes po...

Page 28: ...Reset pour plus d informations sur l utilisation de ce bouton 8 Emplacement de la carte SIM Compatibilit avec le format mini SIM 25x15 mm 2FF uniquement 9 Relais OUT1 OUT2 OUT3 Pilotage de l horloge...

Page 29: ...Error Info Rouge teinte fonctionnement normal Allum e en continu mode BLOCK activ le d clenchement des alertes ne peut alors pas tre enclench Clignote en continu d tection d une erreur de liaison GSM...

Page 30: ...ote certains op rateurs permettent de d finir le code PIN de la carte SIM lors de sa commande 2 3 Installation m canique 1 Percer 4 trous dans un mur suivant la disposition et les cotes dimensionnelle...

Page 31: ...entr e IN4 et la sortie OUT1 est d j r alis en usine c t bo tier Pour le raccordement de l entr e alarme IN5 et des 2 autres sorties OUT2 et OUT3 r f rez vous au sch ma ci dessus et utilisez le c ble...

Page 32: ...pour chaque num ro enregistr un positionnement sur les 50 emplacements disponibles au sein de sa m moire Pour chacun des 5 groupes une ou plusieurs fonctions sur le produit sont autoris es Pour la pr...

Page 33: ...me NOMDUSITE Nom de votre tablissement exemple cole V HUGO 3 3 3 Attribution des droits Etapes Commande envoyer par SMS Description 5 RESET G1 CodePIN R initialisation des droits pour le groupe G1 6 S...

Page 34: ...l alerte correspondante max 10 caract res Exemple newname Confinement 25 SET IN5 LH 1 CodePIN Configuration de l entr e IN5 3 3 6 Activation et param trage de l alarme Etapes Commande envoyer par SMS...

Page 35: ...ie 3 2 2 Gestion du r pertoire et des droits pour effectuer la v rification 31 STATUS CodePIN Indication de l tat du produit l instant courant pour v rifier la configuration 32 SET PIN NEWPINCODE Code...

Page 36: ...nombre total de num ros de t l phone enregistr s en m moire et du nombre de num ros enregistr s dans chaque groupe B TEST TEL GX CodePIN Identification des contacts enregistr s nom et emplacement dan...

Page 37: ...ment utile pour retirer le contact d un groupe car elle est li e au num ro d emplacement et un contact dans 2 groupes 2 emplacements diff rents sans le supprimer dans l autre groupe La suppression d u...

Page 38: ...strateur recevront un SMS d avertissement alertant du d clenchement de l alerte intrusion car l entr e alarme IN4 est d di e la remont e de cette alerte et tous les groupes sauf G5 ont la fonction ALA...

Page 39: ...tive 24 V 16 A Cat gorie de surtension Cat gorie III 300 V OUT1 2 3 et bloc d alimentation Entr e IN4 IN5 Logique Low L de 0 1 0 V Logique High H de 1 5 V 32 V Fr quence module GSM GPRS GSM900 880 915...

Page 40: ...u firmware Heure programm e dans l appareil Date programm e dans l appareil Dur e entre 2 changements de statut d un relais Dur e entre 2 messages d alarme 4 SET NAME BodetGSM CodePIN BodetGSM 0 48 Th...

Page 41: ...ESET G5 CodePIN BodetGSM 0 48 G5_ALARMSMS OFF G5_INCALL1 NO G5_INCALL2 NO G5_INCALL3 NO G5_NEWS OFF G5_SMSFORWARD NO Nom de l appareil Version du firmware Fonction d sactiv e Fonction d sactiv e Fonct...

Page 42: ...e Etat de la fonction appel entrant param tr e 22 SET NAMEIN4 ALERTE A CodePIN BodetGSM 0 48 IN1 No Name IN2 No Name IN3 No Name IN4 ALERTE A IN5 No Name OUT1 ALERTE A OUT2 ALERTE B OUT3 ALERTE C Nom...

Page 43: ...enregistr N d emplacement et groupe attribu au contact 29 TEST TEL G1 CodePIN BodetGSM 0 48 Grp G1 Member 01 MARTIN Nom de l appareil Version du firmware Identification du groupe Liste des contacts e...