Boca Flasher HPNLS-LO Installation Manual Download Page 1

Installation Manual

HPNLS-LO

BocaFlasher.com

1 of 6

REV 10-2020

INTRODUCTION:

The Boca HPNLS-LO is a line voltage fixture that eliminates the need for secondary transformers, making installation contractor 

friendly. The housing is a clear anodized aluminum with a durable finish making it weather and abrasion resistant.  It is UL Listed 

for dry, damp or wet location (model dependent).  See layout drawings for model provided.

1.  Input Voltage: 90-120VAC, 230-277VAC  

2.  Total linear ft per 20A breaker: Lo8 = 120ft @ 120V,

 

280V @ 277V

 

Total linear ft per 20A breaker: Lo6 = 220ft @ 120V,

 

420ft @ 277V

3.  Total linear ft per 15A breaker: Lo8 = 96ft @ 120V,

 

210ft @ 277V

 

Total linear ft per 15A breaker: Lo6 = 160ft @ 120V,

 

320ft @ 277V

ELECTRICAL SPECIFICATIONS:

Fixtures must be installed by a qualified and licensed electrician in 
accordance with all national, state and local electrical codes and 
regulations. If any part of this manual does not meet the necessary

 

codes and regulations, contact the factory for more information

 

before attempting to install.

WARNING: DO NOT LIFT FIXTURE BY CABLES. Do not attempt to install or use the HPNLS-HO fixture without 

reading the installation instructions and safety labels completely. DO NOT ATTEMPT TO INSTALL OR USE THE 

NANOLUME FIXTURE.

 

This could result in permanent damage to both the fixture and the cables. Damage resulting 

from grasping cables and/or putting undue pressure on the cable connections will not be covered under the warranty!

FAILURE TO ADHERE TO THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE. 

DO NOT MODIFY, ALTER OR ATTEMPT TO SERVICE THE HPNLS-HO DOING SO WILL VOID THE WARRANTY.

Max Temp: 55°C

Min. Temp: -40°C

Storage:

  Store in a dry, well-ventilated area when product is not in 

use. Keep the electrical cord away from heated surfaces 

when in use or not in use. If cord shows signs of damage

 

do not use, return product to manufacturer.

Cleaning: 

  Dry and Damp (IP65) Rated Fixtures: 

 

To clean surface use a soft damp cloth.

  Wet (IP68) Rated Fixtures: 

 

To clean surface use a soft cloth with mild soap and water.

MAINTENANCE:

IP60

Dry Listing

Damp Listing

IP65

IP68

Wet Listing

Reviews: