WHE Fan Forced Wall Insert Heaters
INSTALLATION AND OPERATING INSTRUCTIONS
PACKAGING
- Unpack the heater and remove all packaging material.
LOCATION
- The WHE heater is intended for the space heating of small areas that require the additional
robustness and air movement this heater is designed to provide. DO NOT COVER THE HEATER or restrict the
airflow in any way as this can cause overheating.
POSITIONING
- The heater is intended to be vertically or horizontally wall mounted only. Either surface mounted,
using the WHESB or recessed. Do not obstruct the front of the heater for at least 1200mm. Optimum mounting
height is 1m from the floor. For recess mounting provide an opening in the wall 182 x 358 x 80mm.
INSTALLATION
- For surface mounting fix the mounting box to the wall securely. Remove the two screws
securing the front cover and locate the incoming wiring to suit the terminal connection point on the heater. Where
the wiring passes through the recess box use a knockout suitably bushed. For surface mount using four screws fit
the recess box into the surface box. For recess mount, using four screws securely fit the recess box to the wall.