INSTRUCTIONS FOR:-
INDUSTRIAL SPACE HEATER
OUH2-3W Series
IMPORTAN
T: PLEASE READ THESE INSTRUCTIONS, NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS.
USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
Thank you for purchasing a BNThermic product. Manufactured to a high standard, this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
To make sure that you have selected the correct heater for your application,
please read Section 8 on the back page before installation.
1. SAFETY INSTRUCTIONS
1.1 ELECTRICAL SAFETY
WARNING!
It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any
other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety
devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. If in any doubt consult a qualified
electrician.
You must also read and understand the following instructions concerning electrical safety.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the
safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
Installation should always be carried out by a qualified electrician or a competent person in accordance with current electrical regulation.
Ensure that the insulation of all the cables on the appliance is undamaged and safe, before connecting it to the power supply.
Ensure that the cables are always protected against short circuit and overload.
Regularly inspect the power supply cables and plugs etc. for wear or damage and check all connections to ensure that none are loose.
Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that a correctly rated fuse is fitted.
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or replaced by a qualified electrician.
The unit should be protected by a suitably rated isolator and fuse or MCB.
This heater is IP20 rated and is suitable for indoor use only.
The controls and heaters may be fed from a different source and it is essential that all circuit breakers feeding the heating system are
isolated prior to any work being carried out on any of the heaters in the system.
Do not attach this heater to an extension cord it must be hard wired in position.
1.2 GENERAL SAFETY INSTRUCTIONS
Remove all packaging and store it away from children, check the package and
heater for visible damage or tampering.
Familiarise yourself with the applications and limitations of the heater.
Ensure the heater is in good order and condition both physically and
electrically before use. If in any doubt, do not use the unit and contact your
supplier.
Only use recommended attachments and parts. To use unauthorised parts
may be dangerous and will invalidate your warranty.
Keep tools and other items away from the heater when it is in use.
Keep children and unauthorised persons away from the heater, as it gets
hot.
Disconnect from mains and allow to cool before attempting any cleaning or
maintenance.
X
DO NOT
use in areas where hazardous gasses or dusts may be present.
X
DO NOT
locate the heater directly below the power outlet.
X
DO NOT
disassemble the heater for any reason. This heater must be checked
by qualified personnel only.
X
DO NOT
use this heater to perform a task for which it has not been designed.
WARNING!
Ensure you observe the safety distances and mounting heights
and there is no possibility of inflammable materials coming into contact.
2. INTRODUCTION & SPECIFICATION
This heater produces a totally dry heat, no condensation, no gas, no fumes. It reaches maximum heat output within a few minutes of being turned
on. It is quick and easy to install reducing installation costs.
Air temperature can be controlled by the heater’s built-in thermostat (if ordered with
heater) or alternatively by a
remote thermostat. All the 3W range of heaters are designed to operate without requiring a Neutral connection. A “T” on
the end of the model number indicates that an internal thermostat has been factory fitted e.g. OUH2-05-3WT.
Model
OUH2-03-3W
OUH2-05-3W
OUH2-07-3W
OUH2-10-3W
OUH2-15-3W
OUH2-20-3W
OUH2-25-3W
Power
3kW
5kW
7.5kW
10kW
15kW
20kW
25kW
Input supply (No Neutral)
400v ac 3Phase
400v ac 3Phase
400v ac 3Phase
400v ac 3Phase
400v ac 3Phase
400v ac 3Phase
400v ac 3Phase
Dimensions W x D x H (mm)
435 x 405 x 320
435 x 405 x 320
435 x 405 x 320
435 x 405 x 320
565 x 485 x 445
565 x 485 x 445
565 x 485 x 445
Weight
19kg
19kg
19kg
19.5kg
39.5kg
40kg
41kg
Recommended Mounting Height 2.4m
2.4m
2.4m
2.4m
2.8m
2.8m
2.8m
Safety Distance from Heater
2.0m
2.0m
2.0m
2.0m
2.0m
2.0m
2.0m