BN Thermic B16C Instructions Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thank you for purchasing a BN Thermic product. Manufactured to a high standard, this product will, 

if used according to these instructions and properly maintained, give you years of trouble free 

performance. Please ensure instructions remain with your customer for their reference. 

 

 

 

 

 

 

 

 

 

 

 

 SECTION  A – USER INSTRUCTIONS. 

For installation instructions go to page 4 

 

 

1. INTRODUCTION & SPECIFICATION. 

 

 

The B16C Thermostat is an easy to install and use 7 Day, 6/1 

Day or 5 /2  Day Programmable Room Thermostat which offers 

four time and temperature changes each day. It is designed to 

provide automatic time and temperature control for underfloor 

heating using air temperature and a floor sensor. All settings 

are stored in the controller with battery back-up. 

 

B16C- Programmable Heater Controller

 

Programming

 

7 Day, 6+1 Day or 5+2 Day (Default 5+2 Day)

 

Power Supply 

230V ac 50 Hz 16A Maximum Load   (Battery back-up) 

Floor Temperature Sensor 

NTC (10KΩ) +/- 0.5°C at 20°C 

Temperature Range 

1°C to 45°C (Default 5°C to 30°C) 

Display 

LCD + back light that comes on for short period when any button 

pressed. 

Number of Programs Per Day  4 

Tamper Resistant 

Facility for locking all buttons or just temperature adjustment 

buttons. 

Dimensions 

86mm x 86mm x 15mm deep when recessed. Fits standard 

recess boxes. 

Electrical Protection 

Class II        IP20 

Complies with: 

EN 301489-1, EMC Directive 2014/30/EU,  

EN60950-1:2006+a11:2009+a1:2010+a12:2011+ 
a2:2013 

 

 

 

IMPORTANT

: PLEASE READ THESE INSTRUCTIONS, NOTE THE SAFE 

OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS. USE THIS 

PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT 

IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL 

INJURY AND WILL INVALIDATE THE WARRANTY. 

 

INSTRUCTIONS FOR:- 

PROGRAMMABLE CONTROLLER 
Model:- B16C

 

REGISTER

: PLEASE REGISTER THIS PRODUCT ONLINE TO ACTIVATE 

YOUR GUARANTEE AT www.bnthermic.co.uk 

Summary of Contents for B16C

Page 1: ...Default 5 2 Day Power Supply 230V ac 50 Hz 16A Maximum Load Battery back up Floor Temperature Sensor NTC 10K 0 5 C at 20 C Temperature Range 1 C to 45 C Default 5 C to 30 C Display LCD back light that...

Page 2: ...that Monday is 1 Tuesday 2 etc If you don t press a button for 5 seconds display returns to standard mode and you will need to repeat section b Programming The controller is preset to the following ti...

Page 3: ...reture by pressing the or buttons This override will last until the next program period and is shown by both the and symbols 4 When in Manual mode you can override the set tempreture by pressing the o...

Page 4: ...safety contact a qualified electrician Installation should always be carried out by a qualified electrician or a competent person in accordance with current electrical regulation Ensure that the cabl...

Page 5: ...e gang back box having a minimum depth of 35mm 1 Remove the front screen from the thermostat by gently using a screwdriver underneath the front lip to release the two plastic clips Gently pull the scr...

Page 6: ...tactor with the thermostat controlling the coil of the contactor 4 Once all the connections have been made make sure the arrow on the back plate faces upwards and secure to the back box using two scre...

Page 7: ...d N1 Built in sensor only N2 Floor sensor only N3 Built in sensor and floor sensor If floor sensor temperature is higher than its set point A6 load will turn off indicated by flashing until temperatur...

Page 8: ...ts and as such we reserve the right to alter data specifications and component parts without prior notice REGISTER Activate your warranty by registering online at www bnthermic co uk and retain this i...