Page 1: ...nderstand this manual before operating the equipment After reading keep this manual in an easily accessible place P12529 17 10 2019 Copyright 2019 by BMV Technology Co Ltd All rights reserved BestScan S10 Ultrasound System ...

Page 2: ...cers 13 Intended uses 13 Chapter 2 System Setup 14 Operating System 14 Software Updates 14 Charging 14 Goggles 15 Chapter 3 Go Imaging 17 Image Adjustment 17 Imaging modes 17 Freeze Menu 25 Cine and image 31 Patient information 31 Thumbnail image 32 Settings 33 Chapter 4 Troubleshooting and Maintenance 37 Chapter 5 Specifications 42 Chapter 6 Accessories 44 ...

Page 3: ...tment improvement and repair should only be performed by qualified personnel approved by BMV All the replaced parts and supported accessories and consumables relate to the maintenance shall be originally from BMV or others approved by BMV DO NOT make changes or modifications to the software or hardware of this system The electrical equipment complies with relevant standards and the requirements of...

Page 4: ...guide for information on using accessories and peripherals See the manufacturer s instructions for specific information about peripherals Illustration All the illustrations in this user Manual are for reference only The menus settings and parameters of the illustrations may be different from your actual currently use system The content varies depending on the software version preset settings and o...

Page 5: ...anty shall not extend to Malfunction or damage caused by improper use or man made failure Malfunction or damage caused by unstable or out of range power input Malfunction or damage caused by force majeure such as fire and earthquake Malfunction or damage caused by improper operation or repair by unqualified or unauthorized service people Malfunction of the instrument or part whose serial number is...

Page 6: ...the instruction manual 7 Serial Number 8 Manufacture date 9 Manufacture information 10 This product is provided with a CE marking in accordance with the regulations stated in Council Directive 93 42 EEC concerning Medical Devices The number adjacent to the CE marking 0123 is the number of the EU notified body certified for meeting the requirements of the Directive 11 Control Panel Operator system ...

Page 7: ...gital ultrasound diagnostic system supports the following application Bovine Equine Ovine Basic steps 1 Turn the system on Now BMV Scanner is on standby waiting for the BMV Ultrasound App to start 2 Start the BMV Ultrasound App 3 Tap Animal Patient and complete the patient information form 4 Select the type of examination you want to perform 5 Tap Mode and select an imaging mode System features Th...

Page 8: ...nit Power adapter and connecting cable Carrying case Options Probes Available Probe model Type Intended Use Region Applied C5 2 Rectal curve Reproduction Transvaginal L11 4 Rectal linear Reproduction Transvaginal Other Options No Item 1 Video Converter HDMI to VGA S Video 2 Smart Device Android or iOS 3 Remote Viewing Display 4 Power bank ...

Page 9: ...on 1 Light Blue light Turn on Light is flashing quickly Freeze Light is flashing slowly Live scanning Light is on Turn off Light is off Green light Charging Light is flashing Charging finished Light is off 2 Power button Long press Turn on off the system Short press Freeze or unfreeze the image 3 Gain button In Gain Depth menu to increase Gain In parameter menu to increase the parameter 4 Gain but...

Page 10: ...tem 3 Thumbnial Press it for thumbnail 4 Animal patient Press it for patient information menu 5 Probe Type The mode of probe When the connection is successful according to the current use of probe type such as C5 2Ks 6 Exam Type Select the exam type Connect the current type of inspection such as the abdomen etc 7 Guide Line For puncture reserved 8 Battery Smart device battery level Show the curren...

Page 11: ...display bar 18 List of parameters When the instrument is working the specific working status and parameters are shown here 19 Cine bar The information of Cine The concept of the BMV Ultrasound Scanner scanners and software is primarily to provide an easy to use high performance low cost ultrasound platform for teaching and clinical applications Software Method 1 If the BMV Go Scan App is not insta...

Page 12: ...ata error Please delete after a specified website to download again 4 The installation process the user must agree to the installation of the system required permissions 5 After the success of the installation if the application is not open properly please uninstall and reinstall the software 6 Ensure SMS phone calls and other features closed to prevent the application of interference 7 For the fi...

Page 13: ...ink the Wifi from S10 2 Click the wifi ID of S10 scanner each scanner has an ID but similar as 1001906DBA003 3 Input the password 12345678 to connect the smart device to S10 scanner 4 Open the S10 scanner APP on smart device S10 is connected and ready for scanning 1 Press Power Button to switch on the scanner Open app on the smart device The app will request to connect to the internet Click Allow ...

Page 14: ...f users in the United States connect the adaptor to a 240V supply system the equipment shall be connected to a center tapped single phase supply circuit Turning the system on or off Before you begin using the BMV Ultrasound Scanner make sure you have the scanner and also your smart device with the BMV Ultrasound App installed on it Battery manufacturer Shenzhen BoLiMei Co Ltd Produced for BMV Mode...

Page 15: ...eep mode if scanning for a preset time Preparing transducers WARNING While every attempt has been made to make the probe as rugged as possible the crystal array remains vulnerable and should be protected from knocks Even a small knock against a hard object can cause damage to the probe elements situated behind the thin rubber coating on the probe face The probe has a protective sheath covering the...

Page 16: ...ftware updates contact BMV or distributor for new software Charging The battery can be charged with an adaptor type C port It can also be charged with wireless charger WARNING A full discharged battery should be fully charged within 5 hours While in a good condition the battery run time will be 12hours assuming 50 idle time between scans Electrical connection to the power pack is through the gold ...

Page 17: ...e roller at the back for comfortable wearing Power button Long press to power on off the device Volume button Press to up down volume Return key Press to return to last menu Headphone port The port for headphone Micro USB port The port for charging and export the images Notice Please wear I Scan in a safe place without obstacle Please do not wear I Scan when driving or doing any potential safety h...

Page 18: ...the touch pad on side of Goggles Slide Select menu Click Confirm TP touch screen Slide to select menu Click to confirm Return button To return to last menu Power light The light is on when power on the controller Power button To power on off the controller When using keep your hand clean and avoid dust on the device and not touch the mask with hand Wipe the device with fiber cloth in the box ...

Page 19: ...nal amplitude To achieve the best image quality properly adjust the screen brightness gain depth and viewing angle Also use a suitable optimization setting and exam type To display the 2D image Turn on the system Tap B M Mode to select the image mode Adjust the image as needed Intension Action To modify the brightness Adjust gain Adjust TGC Adjust AP do try to adjust gain first before increasing t...

Page 20: ...n again 2 Parameter For more parameter adjusting 3 Gain adjusting Up and down sliding Virtual Roller Adjustment gain 4 Depth adjusting Up and down sliding Virtual Roller Adjustment depth 5 Freeze button To freeze or unfreeze the image 6 Scanning parameter The setting parameters when scanning 7 Focus Adjustable focus area according to different depth 8 Image display area Display image and direction...

Page 21: ...19 The parameter list as below Live scanning with M mode Press adjusting the image mode from B mode to M mode and press adjusting the image mode from M mode to B mode ...

Page 22: ...more parameter adjusting 3 Gain adjusting Up and down sliding Virtual Roller Adjustment gain 4 DR adjusting Up and down sliding Virtual Roller Adjustment DR 5 Freeze button To freeze or unfreeze the image 6 Sample line Guide Line 7 Depth To show depth of image 8 Focus Adjustable focus area according to different depth 9 Scanning parameter The setting parameters when scanning 10 Image display area ...

Page 23: ...om the probe the brighter the color the faster the flow speed while the darker the color the slower the flow speed Power mode provides a non directionally display of blood flow in the form of intensity as opposed to flow velocity DirPower Directional Power Mode provides the additional information of flow direction towards or away from the probe To display the color power image Turn on the system T...

Page 24: ...adjusting 3 Gain adjusting Up and down sliding Virtual Roller Adjustment gain 4 DR adjusting Up and down sliding Virtual Roller Adjustment DR 5 Freeze button To freeze or unfreeze the image 6 Sample line Guide Line 7 Depth To show depth of image 8 Focus Adjustable focus area according to different depth 9 Scanning parameter The setting parameters when scanning 10 Image display area Display image a...

Page 25: ...more parameter adjusting 3 Gain adjusting Up and down sliding Virtual Roller Adjustment gain 4 DR adjusting Up and down sliding Virtual Roller Adjustment DR 5 Freeze button To freeze or unfreeze the image 6 Sample line Guide Line 7 Depth To show depth of image 8 Focus Adjustable focus area according to different depth 9 Scanning parameter The setting parameters when scanning 10 Image display area ...

Page 26: ...ocity and direction utilizing a real time spectral display The horizontal axis represents time while the vertical axis represents Doppler frequency shift PW mode provides a function to examine flow at one specific site for its velocity direction and features Live scanning with PW mode ...

Page 27: ...ase the value and slide your finger to the left to lower the value 2 Adjust the parameters according to the image quality to select the appropriate value to complete the image adjustment Image adjustment is adjusted according to the parameter the model contains the parameters of the parameters see the image parameters there are four ways to adjust Slide adjustment click on a selected parameter it ...

Page 28: ...26 Page adjustment click the two level menu item the system pops up the relevant parameter settings interface Freeze Menu ...

Page 29: ...nd press OK to confirm Now that the comment is displayed in the image area press the annotation long enough to select the comment Select comments to recompile or move location Drag comments out of the image area to delete No Item Description 1 Comment To make comment on image 2 BodyMark To make bodyMark on image 3 Measure To measure on image 4 Save Cine To save Cine 5 Freeze button To freeze or un...

Page 30: ...rk on the image And press BodyMark button to delete the body mark on the image Measure menu This function is valid for frozen images Currently only support for conventional measurements the measurement data can be withdrawn delete clear hide and other operations ...

Page 31: ...29 Distance measure Press to measure distance on the image Press to clear all the measure result Angle measure Press to measure angle on the image Press to clear all the measure result ...

Page 32: ...30 Area measure Press to measure angle on the image Press to clear all the measure result ...

Page 33: ...image M Conventional measurement items Measurement items Function distance Measure the distance between any two points on a vertical line at a time time Measure the time interval between two points on the M image slope The average slope between the two points is calculated by measuring the distance and time of the two points heart rate On the M heart image the time interval between the two cardiac...

Page 34: ...ndividually or as a video individual frames can be saved as still images or the entire loop as a video Cursor Auto Playback The slider position is automatically updated with automatic playback progress Manual Play Click the progress bar to move the slider position Back Touch the screen and slide to the lef Forward Touch the screen and slide to the right ...

Page 35: ...system supports single frame images continuous multi frame image storage single frame image in smart devices Patient information Press for patient information manage menu including New patient New exam Cancel exam Exam list menu Click here to create a new patient directory where you can record patient information Thumbnail image Press for thumbnail menu the saved image is listed in this menu And p...

Page 36: ...34 Settings Press to get the setting menu ...

Page 37: ...be information including probe ID probe battery probe firmware version probe pid version FPGA version wifi firmware version and version of application Exam list Press Exam List to check saved exam information Show the patients who have been treated before ...

Page 38: ...k mode that you display when you boot System Preset Here you can preset some basic information such as language Parameter area location screen orientation Hospital information Manage the hospital information Login Management Manage the login information ...

Page 39: ...37 Image preset Here you can preset the initial parameters in your check type and mode Exam preset Here you can preset the initial check mode under different probes ...

Page 40: ...38 ...

Page 41: ...or disinfecting peripherals No periodic or preventive maintenance is required for the system transducer or accessories other than cleaning and disinfecting the transducer after every use There are no internal c omponents that require periodic testing or calibration All maintenance requirements are described in this ch apter and in the ultrasound system service manual Performing maintenance procedu...

Page 42: ...cation Do not store the transducer in gels or cleaning disinfecting solutions This will lead to premature deterioration of the probe Do not expose the transducer to materials containing the following agents Acetone Methanol Mineral oil Iodine Freon Industrial cleaners Materials containing perfumes lotions gels etc Breakdown Maintenance When the equipment fails the user is forbidden to dismantle th...

Page 43: ...te matter or body fluids Apply the solution to the cloth rather than the surface 3 Rinse with water or wipe with water dampened cloth and then wipe with a dry cloth 4 Mix the disinfectant solution compatible with the transducer following disinfectant label instructions for solution strengths and disinfectant contact duration 5 Wipe surfaces with the disinfectant solution 6 Air dry or towel dry wit...

Page 44: ...PP softwear Wireless charger Mobile Car Charger Fielding bag Introducer Power adaptor and its line Battery Power and charging Removable Li ion battery gives 12h run time Battery charge time 5 0h Only use BMV approved supplied battery 5V vehicle power supply battery charger and DC power adapter CHARGER Input 100 240 VAC 50 60Hz 0 5A Output 5V 2A BMV Vehicle Power Outlet Cigarette Plug Cable 5V DC 2...

Page 45: ...nd monitoring equipment CAN CSA C22 2 No 601 1 M90 2002 Canadian Standards Association Medical Electrical Equipment Part 1 General Requirements for Safety including CSA 601 1 Supplement 1 1994 and CSA 601 1 1B 90 2002 CEI IEC 61157 2007 International Electrotechnical Commission Requirements for the Declaration of the Acoustic Output of Medical Diagnostic Ultrasonic Equipment UL 60601 1 1st Edition...

Page 46: ...arm strain for Fetal Aging Pregnancy Testing Tablet with S10 software installed Use as a viewing device Belt for S10 main unit To hang the S10 Wrist Mount for phone To be used in conjunction with your choice of Phone Tablet Sunshade To be used with tablet when in the field TYPE C Video Converter To transfer the images in other screen Wireless charger Wireless charger for S10 main unit Mobile Car C...