Addr
(hex)
Register Name
Default
Value
(hex)
R/W Description
011B
Ready
0000
R
B
it[1]: 1 … Initial register settings loaded
and fully applied
011D
Revision
R
Camera revision
Table 5-4: More General registers
5.5
Registers for Sequencing
Addr
(hex)
Register
Name
Default
Value (hex)
R/W Description
0120
NofSequ
1
R/W Number of sequences recorded by the ToF sensor
without wait time in between
0121
IntTimeSeq1
05DC
R/W Integration time to be used for recording sequence 1
NOTE: Sequence 0 integration time is set via register
IntegrationTime
0128
ModFreqSeq1
07D0
R/W Modulation frequency to be used for recording
sequence 1
Modulation frequency index:
0.. 5 MHz
1.. 7,5 MHz
2.. 10 MHz
3.. 15 MHz
4.. 20 MHz
5.. 25 MHz
6.. 30 Mhz
or a modulation frequency in multiples of 10kHz
NOTE: Sequence 0 modulation frequency is set via
register
ModulationFrequency
Table 5-5: Registers for Sequencing
5.6
Registers for Illumination Preheating
Addr
(hex)
Register Name
Default
Value (hex)
R/W Description
0150
IllPreheatingFreq
0064
R/W Frequency of the pre-heating modulation signal
in multiples of 10kHz
Allowed values: 100…1500 (1MHz…15MHz)
0151
IllPreheatingDutyCycle 0032
R/W Duty cycle of the pre-heating modulation signal
in percent
Allowed values: 10…90
0110
IllPreheatingTime
0
R/W Sequence 0 illumination preheating
0 … No pre-heating