1-10-9
SW-POINT
VR501
RF-SW
TP502
WF2
C-PB
TP301
WF3
CTL
TP501
V-OUT
J23
WF1
S-INH
TP507
Main CBA Top View
BHM450F01011A
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F001) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
Because a hot chassis ground is present in the power
supply circut, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly, when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
Sensor CBA Top View
BHF300F01012A
BHF300F01012B