SJT-WVF-V Group Control User Manual 

 

(Version 2018) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shenyang Bluelight 

2018.7.9 

 

 

Summary of Contents for SJT-WVF-V

Page 1: ...SJT WVF V Group Control User Manual Version 2018 Shenyang Bluelight 2018 7 9...

Page 2: ...rt and Description 4 2 3 LCD Display Main Menu Description 5 2 4 Group Control Status and Communication 5 2 5 Each Elevator Status and Description 6 2 6 Group Control Board Internal Logic Status 6 2 7...

Page 3: ...evators are assigned to homing floor to serve up peak traffic during the preset time refer to SJT WVF5 user manual for setting the homing floor 1 2 Off Duty Mode One elevator is assigned to serve up t...

Page 4: ...level of menu or to cancel the amendment Right scrolling cursor or to viewing communication status and grouping status in main menu To scroll up one screen to increase parameter value by one or to se...

Page 5: ...er Elevator state A Enter Elevator State H Enter Input Password 0000 General Para Enter Save Para Enter New Password Enter Group able set Enter S X N quotiety K1 2 K2 2 K3 2 Mode select Enter Set time...

Page 6: ...e set to Mode 0 in that elevator main control board Group control function 2 4 Group Control Status and Communication Balance mode Hall calls are being divided into groups so as to serve the hall call...

Page 7: ...t X02 Inspection X10 Full Load X18 X03 Door Interlock Contact X11 Attendant Y N X19 Emergency Stop X04 Speed Change X12 Fault X20 Door Zone X05 Running X13 Fireman X21 Door Fault X06 Down Direction X1...

Page 8: ...e it will display 2 8 Save Parameter After entering into Save Para menu press Enter to select Yes the system will automatically save the amended parameter Success will be displayed if the saving is su...

Page 9: ...t Set Yes for the each elevator in the group bank 2 10 2 S X N quotient The value K1 K2 and K3 are for internal use do not change the factory setting Note S Up Hall Call X Down Hall Call and N Car Cal...

Page 10: ...mode when Off Duty Mode is set to Yes during the prefix finish working hours the group control system will enter Off Duty mode if On Duty Mode is set to No the group control system will never enter On...

Page 11: ...times When On Duty Mode and Off Duty Mode have been set to Yes if the system time is greater than S Start Time and smaller than S Stop Time the Group system will enter the On Duty Mode If the system t...

Page 12: ...wrong non stop floor set in Main control board is not corresponding to the non stop floor set in Group control system the system will have conflict in responding to registered calls like travelling d...

Page 13: ...ly distribute the elevators to average region based on number of floor for example if there is a 20 floors building having 3 car Group control system Elevator A will be distributed to Floor 01 for wai...

Page 14: ...he Homing Floor setup 1 lowest floor so on and so forth 2 11 Setting requirement for Group Control versus elevator numbers A B C 1 On every elevator controller of the group control the setting for fir...

Page 15: ...SJT WVF V Elevator Group Control User Manual Shenyang Bluelight Page 14 Ver 2007 Appendix 1Group Control and Main Control Board System Block Diagram Appendix 2Group Control Board Dimensions...

Page 16: ...t be removed except the Group control card QK 1 and the furthest Main control board See below diagrams Remove the terminal resistors R287 R252 which resistor has marking 620 i e 62 ohm near to J4 of M...