VENT-FREE GAS 

WALL HEATER

OWNER’S OPERATION AND 

INSTALLATION MANUAL

 

WARNING: If the information in this manual is not 

followed exactly, a fire or explosion may result causing 

property damage, personal injury or loss of life.
—  Do not store or use gasoline or other  flammable va

-

pors and liquids in the  vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any 

phone in your building.

• 

Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

— 

Installation and service must be performed by a quali

-

fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

Questions, problems, missing parts? 

Before returning to your retailer, call 

our customer service department at 1-866-762-4050, 8:00 am - 4:30 pm CST, 

Monday through Friday or email

 [email protected]

BLUE FLAME MODELS

B10TNB-B, B10TPB-B

B20TNB-BB, B20TPB-BB

B30TNB-BB, B30TPB-BB

PFS

®

US

Summary of Contents for B10TNB

Page 1: ...phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation an...

Page 2: ...t is installed Provisions for ad equatecombustionandventilationairmustbeprovided Refer to Air For Combustion and Ventilation section on page 7 of this manual WARNING Improper installation adjustment a...

Page 3: ...ory adjusted for use with propane This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases DANGER Carbon monoxide po...

Page 4: ...um input over 6 000 Btu Hr shall not be installed in a bathroom Heaters with a maximum input over 10 000 Btu Hr shall not be installed in a bedroom 3 This heater needs fresh air ventilation to run pro...

Page 5: ...B20TPB BB Ignition Piezo Piezo Gas Type Natural Propane LP Maximum Input Rating 20 000 BTU Hr 20 000 BTU Hr Minimum Input Rating 10 000 BTU Hr 10 000 BTU Hr Pressure Regulator Setting 4 W C 9 W C Inle...

Page 6: ...ymarch Park Quincy MA 02269 9101 This heater is designed for vent free op eration State and local codes in some areas prohibit the use of vent free heaters State of Massachusetts The installation must...

Page 7: ...uate combustion and ventilation air Read the following instructionstoinsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ev...

Page 8: ...tion grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors Th...

Page 9: ...se walls to discolor Figure 4 Mounting Clearances as Viewed From Front of Heater IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enou...

Page 10: ...hipping Remove mounting bracket from back panel Methods For Attaching Mounting Bracket To Wall Use only the last hole on each end of mount ing bracket to attach bracket to wall Attach mounting bracket...

Page 11: ...fastened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at marked locations usin...

Page 12: ...er is firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks Figure 10 Mounting Heater Onto Mo...

Page 13: ...gulator between the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane LP gas CAUTION Avoid damage to regulator Hold gas regu...

Page 14: ...ter valves The installer must supply an external regula tor The external regulator will reduce incom ing gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If you do not...

Page 15: ...s supply piping system Apply mixture of liquid soap and water to gas joints If bubbles form there may be a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply...

Page 16: ...ny electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call th...

Page 17: ...ait one 1 minute before lighting pilot again 8 Turn control knob counterclockwise to desired heating level The main burner should light Set control knob to any heat level between HI and LO CAUTION Do...

Page 18: ...cal Code and for US instal lations the National Electrical Code ANSI NFPA NO 70 WARNING If repairing or replacing any electrical compo nent or wiring the original wire routing colorcodingandsecur ing...

Page 19: ...ure 21 Incorrect Pilot Flame Pattern IMPORTANT Owner s should check pilot flame pattern and burner flame pattern often Incorrect flame patterns indicate the need for cleaning see Care and Maintenance...

Page 20: ...Remove four screws securing front panel 3 Pull front panel forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front panel using...

Page 21: ...ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 20 or replace ODS pilot assembly 5 Check inlet gas...

Page 22: ...r ODS pilot is lit 1 Burner orifice is clogged 2 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 20 2 Contact local gas supplier Delayed ignition of burner s 1 Manif...

Page 23: ...eaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products Heater produces un wanted odors 1 Heater is burning vapors from paint hai...

Page 24: ...t 1 866 762 4050 When calling please have your model and serial numbers of your heater ready SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition heate...

Page 25: ...www bluegrassliving com 25 200455 01A PARTS MODELS B10TNB B B10TPB B 2 3 7 1 8 10 5 6 4 12 14 16 15 9 11 13...

Page 26: ...1 161130 01 Thermostat Valve 1 5 Burner Assembly 1 6 162332 03 ODS Pilot Natural Gas 1 162332 01 ODS Pilot Propane LP Gas 1 7 RV81FIL 4 RV81FIL 9 Regulator 1 8 Cabinet Bracket 1 9 161229 01HT 161229 0...

Page 27: ...www bluegrassliving com 27 200455 01A 3 1 8 10 6 2 7 5 4 17 11 12 15 9 14 16 13 PARTS MODELS B20TNB BB B20TPB BB B30TNB BB B30TPB BB 20 000 BTU Hr Model Shown...

Page 28: ...2 04 162332 04 ODS Pilot NG 1 162332 02 162332 02 ODS Pilot LP 1 7 RV81FIL 4 RV81FIL 9 RV81FIL 4 RV81FIL 9 Regulator 1 8 Cabinet Bracket 1 9 161226 01HT 161226 01HT 161228 01HT 161228 01HT Upper Mesh...

Page 29: ...nty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement parts call Customer Service toll free at 1 866 762 4050 for referral information When call...

Page 30: ...________________________ ________________________________________________________________ ________________________________________________________________ _____________________________________________...

Page 31: ...________________________ ________________________________________________________________ ________________________________________________________________ _____________________________________________...

Page 32: ...warranty covers the cost of part s required to restore this product to proper operating condition and an allowance for labor when provided by a Bluegrass Living Authorized Service Center or a provider...