Parameter
Description
Min Tune
Frequency
Hops
The minimum RF frequency hops on different RF frequency after RF antenna tuning.
Tune
Hysteresis
Index
The runtime RF antenna tune hysteresis index of measured reflected power.
3.3
Device Status
The information about the current status of the
BLUEBOX
shall be read with the
‘Read Device Status’ command as described in protocol technical manuals wh
ere
the status bytes 1 and 2 have the following meaning.
Status Byte
Description
Status Byte 1
Byte whose bits have the following meaning:
Bit
Description
Bit 7
Not used
Bit 6
Not used
Bit 5
RF status (0=off, 1=on)
Bit 4
‘Continuous’ mode (1=enabled)
Bit 3
Not used
Bit 2
Not used
Bit 1
Output 2 status (1=activated)
Bit 0
Output 1 status (1=activated)
Status Byte 2
Byte whose bits have the following meaning:
Bit
Description
Bit 7
Dip switch SW1-4 (1=closed)
Bit 6
Dip switch SW1-3 (1=closed)
Bit 5
Dip switch SW1-2 (1=closed)
Bit 4
Dip switch SW1-1 (1=closed)
Bit 3
Not used
Bit 2
Not used
Bit 1
Input 2 status (1=activated)
Bit 0
Input 1 status (1=activated)