background image

Blue Whale Spa Ltd, 11 Glaisdale Drive East 

 Nottingham, NG8 4GU

 

I

NSTRUCTION 

M

ANUAL

 

 

 
 

 

Summary of Contents for spaTouch

Page 1: ...Blue Whale Spa Ltd 11 Glaisdale Drive East Nottingham NG8 4GU INSTRUCTION MANUAL...

Page 2: ...ed with a system that supports only the TP400 and or TP600 many screens will work correctly but the spa screen will not display correctly and may not control all of your equipment Manufactured under o...

Page 3: ...p is running and changes color when the heater is on A Lock icon is visible if the panel or settings are locked The Menu choices on the right can be selected and the screen will change to show more de...

Page 4: ...can be changed on the left side of the Main Screen is the Set Temperature Touch either the set temperature line or the water temperature to go to the Set Temperature screen See next page Messages At...

Page 5: ...Hold If the Up or Down button is pressed and held the temperature will continue to change until the button is released or the Temperature Range limits are reached Set Temperature Set Inc 101 F Dec Hi...

Page 6: ...s in Below are some examples of 2 speed Pump indicators If the Spa has a Circ Pump a Circ Pump Icon will appear to indicate its activity but outside of Priming Mode the Circ Pump cannot be controlled...

Page 7: ...Cancel When you see only this button whether it is labeled or not it means Back or Exit It appears on editing screens before you have changed any value as well as on all other screens Save Cancel Canc...

Page 8: ...ghlighted the value can be incremented by pressing the up arrow or decremented by pressing the down arrow Back Settings Temp Range Heat Mode Time of Day Filter Cycles Light Cycle Invert Panel Lock Hig...

Page 9: ...the display These ranges can be used for various reasons with a common use being a ready to use setting vs a vacation setting Each range maintains its own set temperature as programmed by the user Th...

Page 10: ...a is con gured for 24HR circulation the heater pump generally runs continuously Since the heater pump is always running the spa will maintain set temperature and heat as needed in Ready Mode without p...

Page 11: ...nce to start Pump 1 in low speed and then again to switch to high speed Also select the other pumps to turn them on The pumps should be running in high speed to facilitate priming If the pumps have no...

Page 12: ...e pump will turn off after a time out period Non Circ Systems The low speed of pump 1 runs when the blower or any other pump is on If the spa is in Ready Mode See page 9 Pump 1 low may also activate f...

Page 13: ...ide freeze protection The water devices will run either continuously or periodically depending on conditions In colder climates an optional freeze sensor may be added to protect against freeze conditi...

Page 14: ...select the Hour Minutes and 12 24 Hour segments Use the Up and Down Buttons to make changes Note This only applies to some systems If power is interrupted to the system Time of Day will be maintained...

Page 15: ...spas may be manufactured with Circ Pump settings that allow programming ltration cycle duration Some circ Modes are pre programmed to operate 24 hours a day and are not programmable Refer to the spa m...

Page 16: ...les are edited see page 15 Invert Panel Selecting Invert Panel will ip the display and the buttons so the panel can be easily operated from inside or outside the hot tub Auxiliary Panel s Speci c Butt...

Page 17: ...mperature and other programmed settings cannot be adjusted Settings Lock allows access to a reduced selection of menu items These include Filter Cycles Invert Information and Fault Log They can be see...

Page 18: ...nation Recalling a Scene To recall a Scene simply press a Scene number Pressing any Scene line which has not yet been stored will simply turn off all spa devices Back Scenes Scene 1 Scene 2 Scene 3 Sc...

Page 19: ...ter from sensor B Demo Mode Demo Mode is not always enabled so it may not appear This is designed to operate several devices in a sequence in order to demonstrate the various features of a particular...

Page 20: ...r to change certain parameters based on personal preference Temp Display Change the temperature between Fahrenheit and Celsius Time Display Change the clock between 12hr and 24hr display Reminders Tur...

Page 21: ...Signature Displays the checksum for the system configuration file Heater Voltage Feature not used on CE rated systems Displays the operating voltage configured for the heater Heater Wattage as Configu...

Page 22: ...ground fault or other unsafe condition and the power to the spa must be shut off until a service person can correct the problem Forcing the GFCI Trip Test North America Only The installer can cause t...

Page 23: ...Unknown After the pump has been running for 1 minute the temperature will be displayed Possible freezing condition A potential freeze condition has been detected or the Aux Freeze Switch has closed Al...

Page 24: ...eater to start it The spa is shut down After the problem has been resolved you must reset the message to restart heater start up See Flow Related Checks below The heater is too hot M030 One of the wat...

Page 25: ...Communications error The control panel is not receiving communication from the System Call for Service Test software installed The Control System is operating with test software Call for Service F or...

Page 26: ...036 North America Only May indicate an unsafe installation Contact your dealer or service organization A pump may be stuck on M034 Water may be overheated POWER DOWN THE SPA DO NOT ENTER THE WATER Con...

Page 27: ...istry with a test kit and adjust with the appropriate chemicals Clean the Filter May appear on a regular schedule i e every 30 days Clean the lter media as instructed by the manufacturer See HOLD on p...

Page 28: ...conditioned for maximum life Treat the wood May appear on a regular schedule i e every 180 days Wood skirting and furniture should be cleaned and conditioned per the manufacturers instructions for ma...

Page 29: ...ot tub may be injurious to your health Warning Maintain water chemistry in accordance with the Manufacturers instructions Warning The equipment and controls shall be located not less than 1 5 meters h...

Page 30: ...BEFORE SERVICING EEP ACCESS DOOR CLOSED Index Symbols 12 hr and 24 hr display 20 A A B Temps 19 Auxiliary Panels s 16 C Celsius 20 Circulation 10 12 15 Cleanup 20 Clean up Cycle 13 Color 21 D Demo Mo...

Page 31: ...Scenes 18 Set Temperature 5 Settings 9 10 Spa Screen 6 Spa Status 3 System Information 21 T Temperature Range 3 Temperature Ranges 9 Time of Day 2 14 U Unlocking 17 Utilities 19 V Values Increment Dec...

Page 32: ...g the water clean Remember to only add small quantities of chemicals to your water as once it is dissolved into the water it is impossible to take any out Sanitiser Sanitiser chlorine or bromine can b...

Page 33: ...only things you need to put into your water to keep it clean There are however various other things that affect the quality of your water as the tub is used All of these chemicals should be used spari...

Page 34: ...months After three months it is recommended that you drain the tub clean the shell and jets and then refill with clean water Cleaning your filters is very important There are a number of ways to clean...

Page 35: ...HOUSEHOLD CLEANING PRODUCTS dilute the chemical with water according to the directions on the bottle Make sure you use enough water to completely submerge one filter If you have room you can add more...

Reviews: