Gas Conversion and Specifications
NOTE, Pin
rotated for LPG
Gas Regulator
NOTE: The regulator supplied is convertible between Natural Gas and LPG, but it’s outlet pressure
is fixed ex-factory and is NOT to be adjusted.
1.
Ensure that the gas supply is turned ‘OFF’ at the mains.
2.
Unscrew the hexagonal cap (23 mm A/F) from the regulator.
3.
Un-clip the plastic pin from the cap, rotate the pin and re-fit it back to the cap the correct way for
the gas type to be used.
(Either ‘LP’ or ‘NAT’ should be visible on the flank of the pin once
re-fitted to the cap)
.
4.
Screw the cap back into the regulator.
Gas Type Identification Label
On completion of the gas conversion, replace gas type identification label, located at:-
- The rear of the unit, above the gas connection point.
- Beside the rating plate.