Bludee AC800 User Manual Download Page 5

   

                                                                                                                                                          AC800  V2.00 

 

3/16 

 

General safety guide 

 

 

This equipment must only be operated by qualified technicians

 

Read the instruction manual carefully before operating this equipment. If there is anything you do not fully 
understand, please contact your distributor or manufacturer. We like to help. 

 

The  refrigerant  storage  cylinder  contains  liquid  refrigerant  under  high  pressure.  Overfilling  of  the  storage 
cylinder may cause violent explosion. Do not disable the overfill safety protection of this machine. Always 
keep the cylinder on the load cell platform whenever the machine is operating. 

 

Only use cylinder which is supplied with this equipment or recommended by the manufacturer. 

 

Always use this machine in a well-ventilated area, avoid inhaling refrigerant and/or oil vapors, always read 
material safety instructions of refrigerant and oil packaging, for related warning and care. 

 

Always switch off the machine and disconnect the power cable before removing any covers or servicing this 
machine, to avoid electric shock which can be fatal. 

 

Never use compressed air to test for leaks on the vehicle or this equipment!

 

 

Wear  safety  goggles  and  gloves  to  protect  eyes  and  skin  from  contact  with  refrigerant.  Liquid  refrigerant 
when  it  comes  in  contact  with  the  human  skin  or  eyes  will  cause  frostbite  and/or  blindness.  If  accidental 
contact  is made  with  eyes  or  skin,  wash  the  affected  area  with  plenty  of  water  immediately  and  contact  a 
doctor if required. 

 

Avoid using the machine in very hot or flammable areas. 

 

Store the machine in a well ventilated cool area when not in use. 

 

Avoid using extension power cable thinner than 1.5mm

(10amp current carrying capacity). 

 

Keep gasoline or other flammable substances away from the equipment. 

 

For  the  1234yf  machine,  once  a  leak  is  detected  in  the  unit,  switch  off  the  equipment  by 
pressing the Emergency stop button and contact your distributor or service dealer. 

 
 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for AC800

Page 1: ...AC800 V2 00 AC800 USER MANUAL Service and support 443 380 0088 www bludee com...

Page 2: ...cifications contained in this manual are based on the latest information available at the time of publication The right is reserved to make changes at any time without obligation to notify any person...

Page 3: ...ting procedure 9 Recovery function 9 Evacuation function 9 Oil injection function 9 Refrigerant charging function 10 Tank fill 10 Flushing function COR Compressor Oil Recovery Optional 11 Automatic fu...

Page 4: ...re 20bar Charge speed 2Kg Min max LCD display 4 3 inch TFT full color High pressure gauge range 1bar 40bar Low pressure gauge range 1bar 22bar A C database included update through USB port Automatic s...

Page 5: ...or related warning and care Always switch off the machine and disconnect the power cable before removing any covers or servicing this machine to avoid electric shock which can be fatal Never use compr...

Page 6: ...fold and solenoid assembly 6 Vacuum pump 7 Compressor 8 Front wheel 9 Rear wheel 10 Gas tank support 11 Filter drier 12 Gas storage tank 13 Oil accumulator flush oil accumulator 14 Condenser fan 15 LC...

Page 7: ...iew upper part Control panel Left view lower part Sight glass Machine with flush only High side manometer Low side manometer LCD screen and keypad New PAG vessel Used oil vessel UV dye vessel Optional...

Page 8: ...er part Manual air purge version basic Left View upper part Automatic air purge version optional Back View upper part Thermal printer Air purge valve Tank manometer Refrigerant hoses fitting HP LP Pow...

Page 9: ...s such as UV dye leak stopper and cooling booster and contaminants moisture metal and rubber particles etc are mainly mixed or dissolved in compressor oil the flush is very important not only for A C...

Page 10: ...nect the adaptor to the liquid port leave the cylinder upright and open the liquid valve on the cylinder Set the amount of refrigerant to be transferred into the machine storage cylinder once the sele...

Page 11: ...sure rise during the 3 minute pause At the completion of recovery the machine will display and print the total amount of refrigerant recovered and oil if any Evacuation function Select Vacuum evacuati...

Page 12: ...ow the instruction displayed on the touch screen to purge the remainder of refrigerant left in the discharge hose into the vehicle A C system This will make certain that 100 of the selected amount of...

Page 13: ...1kg or more refrigerant Flushing refrigerant will be recovered and purified automatically at the end of the flushing process and stored in the storage cylinder ready for re use For some A C system equ...

Page 14: ...operations of recovery vacuum oil injection and charge Can reset to re record A dynamic code is needed for access Unit settings To set metric or imperial unit of measurement In the interface of unit s...

Page 15: ...te the integrity of the machine If the machine is used on badly contaminated A C systems frequently it is recommended that more frequent vacuum pump oil changes are made and main filter replacements a...

Page 16: ...ck OpenFile to select update to update e g file AC800_V2 01 for main program update or Database_V2 02 for database update Then click Connect the PC displays the following message Click Program_load fo...

Page 17: ...orced to make The remaining operation number is displayed when machine turns on Upon 480 operations having been made the machine displays the following message and users can continue using the equipme...

Page 18: ...in unit 1 BZ030017 3m red service hose 1 BA030016 3m blue service hose 1 BZ130037 HP quick coupler 1 BZ130038 LP quick coupler 1 DZ160033 30A fuse 1 DZ180034 Update cable with USB 1 WJ010007 HP LP blo...

Reviews: