Caring for your equipment 

 

Keep your equipment clean and well maintained at all times. 

 

Keep  service  hoses  stored  on  the  storage  adapters  when  not  in  use,  to  avoid  dirt  and  dust 

contaminating the internals of the couplers which will then end-up in the vehicle A/C system, which 
can cause serious system malfunction. 

 

Always clean vehicle A/C system service ports before connecting machine quick couplers on to 

the service ports. 

 

Keep the system stored in a clean area and away from direct sunlight and artificial heat source, 

when not in use. 

 

Perform  regular  services  on  the  system  as  recommended  by  the  manufacturer.  Ignoring  and 

skipping services will deteriorate the integrity of the machine. 

 

If the machine is used on badly contaminated A/C systems frequently, it is recommended that 

more  frequent  vacuum  pump  oil  changes  are  made,  and  main  filter  replacements  are  performed. 
Contaminated  vacuum  pump  oil  will  cause  the  internal  corrosion  of  the  vacuum  pump,  which 
eventually will cause the failure of the vacuum pump. A contaminated main filter will decrease the 
refrigerant purity.   

 

Do not bump or move the machine when the technician is in the process of charging a vehicle, 

this can affect the charging accuracy. 

 

If the machine is bumped or knocked down accidentally, make calibration again and check for 

possible leaking. 

 

DO NOT

 use compressed air to test for leaks. 

 

If  the  technician  is  not  sure  about  the  correct  way  of  operating  the  machine,  please  do  not 

hesitate to contact your distributor or manufacturer. We always like to help you. 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for AC800

Page 1: ...AC800 V2 00 AC800 USER MANUAL Service and support 443 380 0088 www bludee com...

Page 2: ...cifications contained in this manual are based on the latest information available at the time of publication The right is reserved to make changes at any time without obligation to notify any person...

Page 3: ...ting procedure 9 Recovery function 9 Evacuation function 9 Oil injection function 9 Refrigerant charging function 10 Tank fill 10 Flushing function COR Compressor Oil Recovery Optional 11 Automatic fu...

Page 4: ...re 20bar Charge speed 2Kg Min max LCD display 4 3 inch TFT full color High pressure gauge range 1bar 40bar Low pressure gauge range 1bar 22bar A C database included update through USB port Automatic s...

Page 5: ...or related warning and care Always switch off the machine and disconnect the power cable before removing any covers or servicing this machine to avoid electric shock which can be fatal Never use compr...

Page 6: ...fold and solenoid assembly 6 Vacuum pump 7 Compressor 8 Front wheel 9 Rear wheel 10 Gas tank support 11 Filter drier 12 Gas storage tank 13 Oil accumulator flush oil accumulator 14 Condenser fan 15 LC...

Page 7: ...iew upper part Control panel Left view lower part Sight glass Machine with flush only High side manometer Low side manometer LCD screen and keypad New PAG vessel Used oil vessel UV dye vessel Optional...

Page 8: ...er part Manual air purge version basic Left View upper part Automatic air purge version optional Back View upper part Thermal printer Air purge valve Tank manometer Refrigerant hoses fitting HP LP Pow...

Page 9: ...s such as UV dye leak stopper and cooling booster and contaminants moisture metal and rubber particles etc are mainly mixed or dissolved in compressor oil the flush is very important not only for A C...

Page 10: ...nect the adaptor to the liquid port leave the cylinder upright and open the liquid valve on the cylinder Set the amount of refrigerant to be transferred into the machine storage cylinder once the sele...

Page 11: ...sure rise during the 3 minute pause At the completion of recovery the machine will display and print the total amount of refrigerant recovered and oil if any Evacuation function Select Vacuum evacuati...

Page 12: ...ow the instruction displayed on the touch screen to purge the remainder of refrigerant left in the discharge hose into the vehicle A C system This will make certain that 100 of the selected amount of...

Page 13: ...1kg or more refrigerant Flushing refrigerant will be recovered and purified automatically at the end of the flushing process and stored in the storage cylinder ready for re use For some A C system equ...

Page 14: ...operations of recovery vacuum oil injection and charge Can reset to re record A dynamic code is needed for access Unit settings To set metric or imperial unit of measurement In the interface of unit s...

Page 15: ...te the integrity of the machine If the machine is used on badly contaminated A C systems frequently it is recommended that more frequent vacuum pump oil changes are made and main filter replacements a...

Page 16: ...ck OpenFile to select update to update e g file AC800_V2 01 for main program update or Database_V2 02 for database update Then click Connect the PC displays the following message Click Program_load fo...

Page 17: ...orced to make The remaining operation number is displayed when machine turns on Upon 480 operations having been made the machine displays the following message and users can continue using the equipme...

Page 18: ...in unit 1 BZ030017 3m red service hose 1 BA030016 3m blue service hose 1 BZ130037 HP quick coupler 1 BZ130038 LP quick coupler 1 DZ160033 30A fuse 1 DZ180034 Update cable with USB 1 WJ010007 HP LP blo...

Reviews: