background image

METAL SHIELD

1/2 NPT
(TD MODELS)

NOTE: * CONTROL MUST NOT BE MOUNTED
IN THIS HIGH TEMPERATURE AREA.

*

4 7/16

(113)

8 3/4

(222)

10 1/16

(256)

7 1/4

(184)

TO INSTALL:
IMPORTANT - DO NOT disconnect lead wires from the

Control Panel when installing.

1. Locate the warmer and control panel over the

countertop cutout. Pass the control through the

opening, then mount the control to the rear of the apron.

2. Apply a bead of silicone adhesive/sealant to the gasket

supplied on the underside of the warmer flange, then seat

the warmer onto the countertop. Properly position.

3. From underneath, insert a screwdriver into the "slots" on

the wellslok frame and twist the "ears" outward to secure

the flange tightly to the countertop (see detail).

4. Mount the master control panel to the front of the

counter apron using the screws supplied.

INSTALLATION INSTRUCTIONS

41941-1   REV (-)

INSTALLATION INSTRUCTIONS

BUILT-IN ROUND FOOD WARMERS

MODELS SS-8T (D)

WELLS/BLOOMFIELD * VERDI, NV

ELECTRICAL

MODEL

VOLTS

WATTS

AMPS

PHASE

WIRING

TEMP.

FIELD

GAUGE

RATING

SS-8T

SS-8T

SS-8T

SS-8TD

SS-8TD

SS-8TD

240

208

120

240

208

120

825

620

825

825

620

825

6.9

3.0

3.4

6.9

3.0

3.4

SINGLE

SINGLE

SINGLE

SINGLE

SINGLE

SINGLE

14 AWB Cu

14 AWB Cu

14 AWB Cu

14 AWB Cu

14 AWB Cu

14 AWB Cu

90°C

90°C

90°C

90°C

90°C

90°C

CUTOUT DETAILS

PRODUCT DIMENSIONS

INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:

1. This appliance shall be installed in an all metal counter

with suitable wiring and control enclosures conforming to

national and local electrical codes.

2. Electrical component temperatures, including wiring, within

and surrounding the appliance must be monitored in the

end use installation for suitability.

3. Electrical grounding of all dead metal parts must be

reliably connected to the grounding means of the appliance

and must comply with the requirements outlined in the

appropriate Underwriters Laboratories Inc. classification,

national and local electrical codes.

4. Increased clearances are required if storage of combustible

materials is in close proximity to this appliance.

5. Unit shall be accessible for servicing from the bottom.

6. The name/rating plate information shall be accessible.

7. For water and waste connections: This appliance is to be

installed to comply with the applicable federal, state or

local plumbling codes.

TO FABRICATE:
1. Lay out "cutout" dimensions on countertop and front

apron as shown in cutout details above.

2. Cut and/or drill holes as required in countertop and apron

3. Must be accessible for servicing from the bottom.

UNIT MUST BE INSTALLED IN AN ALL METAL COUNTER.

THE INSTALLATION OF RECOGNIZED COMPONENT UNITS
REQUIRES ADDITIONAL EVALUATIONS TO UNDERWRITERS
LABORATORIES INC. STANDARDS.

UNIT TO THE NEAREST SURFACE

SEE CONDITIONS OF ACCEPTABILITY BELOW

4

(102)

8 1/2

(216)

(25)

1

1

(25)

FRONT

BOTTOM

SIDE

BACK

CLEARANCES

WHEN CONTROL BOX IS LOCATED BELOW THE
UNIT, FRONT CLEARANCE CAN BE 2 INCHES.

NOTE: DEPENDING ON THE INSTALLATION,
CLEARANCES CAN BE CHANGED UPON
FURTHER EVALUATIONS TO UL STANDARDS.

SUGGESTED CLEARANCES FROM

5/16 DIA

17/64 DIA
2 PL

13/32 DIA

FRONT PANEL CUTOUT

TOP CUTOUT

5 3/16

(132)

9

(229)

7 1/4

(184)

2 1/32

(52)

7/8

(22)

1 3/4

(44)

WARMER FLANGE

GASKET

WELLSLOK

COUNTERTOP

SCREWDRIVER

INCHES

(MM)

Reviews: