background image

(102)

4

(70)

2 3/4

(149)

5 7/8

(159)

6 1/4

(210)

8 1/4

(241)

9 1/2

CONDUIT

(ULTD MODELS)

1/2 NPT

90°C

14 AWB Cu

SINGLE

3.4

825

220-240

SS-4EUTD

90°C

14 AWB Cu

SINGLE

3.4

825

220-240

SS-4EUT

INSTALLATION INSTRUCTIONS

ELECTRICAL CODES.

NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND

 

supplied.

5. Mount the control panel to control box using screws

46221-1   REV (A)

INSTALLATION INSTRUCTIONS

BUILT-IN ROUND FOOD WARMERS

MODELS SS-4ULT (D, EUT, EUTD)

WELLS/BLOOMFIELD * VERDI, NV

ELECTRICAL

MODEL

VOLTS

WATTS

AMPS

PHASE

WIRING

TEMP.

FIELD

GAUGE

RATING

SS-4ULT

SS-4ULT

SS-4ULT

SS-4ULTD

SS-4ULTD

SS-4ULTD

240

208

120

240

208

120

825

620

825

825

620

825

6.9

3.0

3.4

6.9

3.0

3.4

SINGLE

SINGLE

SINGLE

SINGLE

SINGLE

SINGLE

14 AWB Cu

14 AWB Cu

14 AWB Cu

14 AWB Cu

14 AWB Cu

14 AWB Cu

90°C

90°C

90°C

90°C

90°C

90°C

CUTOUT DETAILS

PRODUCT DIMENSIONS

unit down to countertop (see detail at right).

wellslok flange and twist outward (clockwise) to tighten

4. From underneath, insert screwdriver into slots on

into front panel cutout.

3. Seat warmer onto countertop and the mount control box

panel cutout.

Pass control box through countertop cutout and front

2. Locate warmer and control box over countertop cutout.

to the underside of warmer flange.

to countertop, apply a bead of silicone adhesive/sealant

RECOMMENDATION: Before final seating of modular section

gasket is applied.

from the outside edge. Remove the paper backing as the

perimeter of the appliance mounting flange, about 1/4 inch

1. Press the self sticking 'gray' gasket material along the

Control Panel when installing.

IMPORTANT - DO NOT disconnect lead wires from the

TO INSTALL:

 

3. Cut out holes. 

apron using the control box as a template.

2. Lay out and fabricate control panel holes in counter

apron.

1. Lay out "cutout" dimensions on countertop and front

TO FABRICATE:

 

the unit to avoid contact with elevated temperatures.

recommended that a baffle be placed 8 1/2 inches below

3. If storage is to be used underneath the unit, it is

2. Unit shall be accessible for servicing from the bottom.

and 8 inches to a surface below the unit.

4 inches to front wall, 1 inch to back and side walls,

Wooden and Metal Installation: DO NOT install closer than

1. Required installation clearances:

OUTLINED BELOW UPON INSTALLATION:

INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY

CLEARANCES

BACK

SIDE

BOTTOM

FRONT

(25)

1

1

(25)

(203)

8

(102)

4

MINIMUM CLEARANCE REQUIRED

FROM UNIT TO THE NEAREST SURFACE

(124)

4 7/8

(127)

5

(75)

2 15/16

(102)

4

(178)

7

FRONT PANEL CUTOUT

TOP CUTOUT

WARMER FLANGE

GASKET

WELLSLOK

COUNTERTOP

SCREWDRIVER

IS LOCATED TO THE FRONT OF THE FIXTURE.

MOUNT APPLIANCE SO THAT THE CONTROL PANEL

IMPORTANT:

PANEL

CONTROL

MASTER

INCHES

(MM)

Reviews: