L3

L2

L1

UNIT TO THE NEAREST SURFACE

ELECTRICAL CODES.

NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND

 

volts to ground.

2. Do not connect to a circuit operating at more than 150

Panel. Check nameplates for voltage and phase.

knockout to terminal block supplied within the Master Control

supply leads (see 'wiring requirements' label) through conduit

1. Final connection is accomplished by bringing proper power

TO WIRE:

 

3. Connect 1'' drain connection to suitable drain line.

female N.P.T. drains.

2. Models without manifold are supplied with individual 1/2''

one end of the manifold.

discretion of the fabricator. Install and tighten pipe plug in

Model "DM" and "TDM" units. Location of valve handle is at the

1. A drain manifold complete with valve is supplied on all

TO PLUMB:

 

supplied.

4. Mount Control Panel onto electrical box using screws

12 AWB Cu

FIELD WIRING GAUGE

21.6

15.0

208

4500

MOD-500

AMPS PER LINE 3 PHASE

VOLTS

WATTS

MODELS

SINGLE

12 AWB Cu

25.0

17.0

240

6000

MOD-500

12 AWB Cu

29.8

19.5

208

6200

MOD-500T

12 AWB Cu

34.4

22.1

240

8250

MOD-500T

11.2

13.0

14.6

16.9

16.9

14.6

13.0

11.2

AMPS

PHASE

'T' MODELS

         WELLS/BLOOMFIELD * VERDI, NV

PANEL

CONTROL

MASTER

FRONT PANEL CUTOUT

TOP CUTOUT

SCREWDRIVER

COUNTERTOP

WELLSLOK

GASKET

WARMER FLANGE

FRONT OF THE FIXTURE.

MANIFOLD ARE LOCATED TO THE

THE CONTROL PANEL AND DRAIN

MOUNT APPLIANCE SO THAT BOTH

IMPORTANT:

3. Mount Control Box to apron cutout as shown in drawing.

required to secure flange tightly to countertop.

Wellslok frame and twist "ears" outward (clockwise) as

2. From underneath, insert screwdriver into "slots" in

flange.

to underside of gray gasket material supplied on mounting

to countertop, apply a bead of silicone adhesive/sealant

RECOMMENDATION: Before final seating of modular section

modular section into countertop cutout and position.

counter top cutout, then through apron cutout. Lower

1. Tilt and pass Control Panel and electrical box through

Master Control Panel when making installation.

IMPORTANT - DO NOT disconnect "lead wires" from the

TO INSTALL:

 

4. Unit shall be accessible for servicing from the bottom.

3. Cut out holes. 

apron using the control box as a template.

2. Layout and fabricate control panel holes in counter

apron.

1. Layout "cutout" dimensions on countertop and front

TO FABRICATE:

 

the unit to avoid contact with elevated temperatures.

recommended that a baffle be placed 8 1/2 inches below

3. If storage is to be used underneath the unit, it is

2. Unit shall be accessible for servicing from the bottom.

6 3/4 inches to a surface below the unit.

6 inches to front wall, 1 inch to back and side walls, and

Wooden and Metal Installation: DO NOT install closer than

1. Required Installation Clearances:

OUTLINED BELOW UPON INSTALLATION:

INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY

 

FOR DM AND TDM MODELS ONLY.

MANIFOLD WITH 1" INTERNAL NPT VALVE IS SUPPLIED

ARE FIELD CONVERTIBLE TO SINGLE PHASE. THE DRAIN

NOTE: MOD-500 UNITS ARE SHIPPED THREE PHASE AND

CUTOUT DETAILS

INSTALLATION INSTRUCTIONS

         37099-5     REV (-)

INSTALLATION INSTRUCTIONS

BUILT-IN MODULAR WARMERS

MOD 500 SERIES (T, TD, TDM)

(25)

(25)

(171)

(152)

MINIMUM CLEARANCE REQUIRED FROM

BACK

SIDE

BOTTOM

FRONT

1

1

6 3/4

6

ELECTRICAL

CLEARANCES

PRODUCT DIMENSIONS

'D' MODELS ONLY

INTERNAL N.P.T.

1/2 INCH

'T' MODELS

8 AWB Cu

8 AWB Cu

8 AWB Cu

8 AWB Cu

75°C

75°C

75°C

75°C

RATING

TEMP.

3 PHASE

1 PHASE

ALL MODELS WITH A "D" OR "DM" SUFFIX HAVE THE SAME ELECTRICAL SPECIFICATIONS AS THE STANDARD MOD-500 OR MOD-500T MODELS.

INCHES

(MM)