background image

PRINTED IN UNITED STATES OF AMERICA

WELLS BLOOMFIELD, LLC

2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439

www.wellsbloomfield.com

telephone: 775-689-5703

fax: 775-689-5976

IMPORTANT:  DO NOT DISCARD THIS MANUAL 

This manual is considered to be part of the appliance and is to be given to the OWNER or 

MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of 

this appliance.  Additional manuals are available from your WELLS DEALER. 

 

THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR 

INSTALLING THIS APPLIANCE.

  Contact your WELLS DEALER if you have any 

questions concerning installation, operation or maintenance of this equipment. 

OPERATION MANUAL 

 

WELLS 

BUILT-IN 

WARMERS 

with 

INFINITE SWITCH 

CONTROL 

 

including 

Drain/Manifold 

 Models

 

 
 

 

Includes 

INSTALLATION 

USE & CARE 

012 

p/n 

303309

 Rev. C  ECN-13420   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 M012  

08

0215  cps 

Model SS-10 

Model MOD-300 

Model SS-206 

Summary of Contents for MOD-300

Page 1: ...sponsible for TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Con...

Page 2: ...ote of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchandis...

Page 3: ...mance and a long economical service life This manual contains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its optimum...

Page 4: ...E CONTROL KNOB will rotate without stopping with PREHEAT and OFF having obvious detents The OFF position is a positive OFF i e the switch is positively held in the open position NOTE Since the infinit...

Page 5: ...s recommended or authorized by the manufacturer or its agents Operators of this appliance must be familiar with the appliance use limitations and associated restrictions Operating instructions must be...

Page 6: ...and other installation details refer to the Installation Instructions supplied with the warmer 2 Cutout dimensions for warmer units and control panels are listed on the Installation Instructions prov...

Page 7: ...meet or exceed applicable specifications of local codes and of the National Electrical Code PLUMBING INSTALLATION For use in the State of Massachusetts this appliance must be installed in compliance w...

Page 8: ...to run dry is NOT covered by warranty Damage caused by adding water to a dry warmer when hot is NOT covered by warranty PRE HEATING THE WARMER 1 Place desired pan s or inset s with appropriate adapte...

Page 9: ...g between wet and dry operation in any individual warmer is NOT recommended 4 DO NOT use metal tools steel wool or caustic or abrasive cleanser to clean warmer pan WARMERS WITH MANIFOLDED DRAIN 1 Mani...

Page 10: ...lange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating element causing a potential fire and or elect...

Page 11: ...accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control OFF Co...

Page 12: ...nal damage Contact your Authorized Wells Service Agency for repairs Warmer slow to heat Mineral deposits on pan acting as a insulator Clean pan s with delime cleaner Wired to wrong voltage Verify supp...

Page 13: ...a harsher environment Wells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless steel however is mostly iron and will rust pit an...

Page 14: ...PT HW SMP or 1 side of TMPT to hold one 11 qt and one 7 qt inset 21621 ADAPTER TOP convert 12 x 20 warmer to hold two 7 qt insets 21502 ADAPTER TOP convert 12 x 20 warmer to hold two 4 qt and two 2 qt...

Page 15: ...rvice RESTAURANT _____________________________ LOCATION _____________ INSTALLATION DATE ________________________ TECHNICIAN ___________ SERVICE COMPANY ________________________________________________...

Page 16: ...ION CUSTOMER SATISFACTION Commercial Food Equipment Service Association Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association PRINTED IN UNITED STATES OF AMERICA WELLS...

Reviews: