(356)
14
(197)
7 3/4
(57)
2 1/4
(600)
23 5/8
(749)
29 1/2
(356)
14
(159)
6 1/4
(248)
9 3/4
(44)
1 3/4
(572)
22 1/2
(725)
28 1/2
(105)
4 1/8
(127)
5
(79)
3 1/8
(325)
12 7/8
90
°
C
90
°
C
75
°
C
75
°
C
RATING
TEMP.
MOD-200 OR MOD-200T MODELS.
SPECIFICATIONS AS THE STANDARD
SUFFIX HAVE THE SAME ELECTRICAL
ALL MODELS WITH A 'D' OR 'DM'
'D' MODELS ONLY
INTERNAL N.P.T.
1/2 INCH
WELLS/BLOOMFIELD * VERDI, NV
PANEL
CONTROL
MASTER
ELECTRICAL CODES.
NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND
volts to ground.
2. Do not connect to a circuit operating at more than 150
Panel. Check nameplates for voltage and phase.
knockout to terminal block supplied within the Master Control
supply leads (see 'wiring requirements' label) through conduit
1. Final connection is accomplished by bringing proper power
TO WIRE:
3. Connect 1'' drain connection to suitable drain line.
female N.P.T. drains.
2. Warmers with 'D' suffix are supplied with individual 1/2''
end of the manifold.
discretion of the fabricator. Install and tighten pipe plug in one
"DM" and "TDM" units. Location of valve handle is at the
1. A drain manifold complete with valve is supplied on all Model
TO PLUMB:
supplied.
4. Mount Control Panel onto electrical box using screws
FRONT PANEL CUTOUT
TOP CUTOUT
SCREWDRIVER
COUNTERTOP
WELLSLOK
GASKET
WARMER FLANGE
FRONT OF THE FIXTURE.
MANIFOLD ARE LOCATED TO THE
THE CONTROL PANEL AND DRAIN
MOUNT APPLIANCE SO THAT BOTH
IMPORTANT:
3. Mount Control Box to apron cutout as shown in drawing.
required to secure flange tightly to countertop.
Wellslok frame and twist "ears" outward (clockwise) as
2. From underneath, insert screwdriver into "slots" in
flange.
to underside of gray gasket material supplied on mounting
to countertop, apply a bead of silicone adhesive/sealant
RECOMMENDATION: Before final seating of modular section
modular section into countertop cutout and position.
countertop cutout, then through apron cutout. Lower
1. Tilt and pass Control Panel and electrical box through
Master Control Panel when making installation.
IMPORTANT - DO NOT disconnect "lead wires" from the
TO INSTALL:
4. Unit shall be accessible for servicing from the bottom.
3. Cut out holes.
apron using control box as a template.
2. Layout and fabricate control panel holes in counter
apron.
1. Layout "cutout" dimensions on countertop and front
TO FABRICATE:
the unit to avoid contact with elevated temperatures.
recommended that a baffle be placed 8 1/2 inches below
3. If storage is to be used underneath the unit, it is
2. Unit shall be accessible for servicing from the bottom.
may be 1 inch.
control box is located below the unit, the front clearance
and 6 3/4 inches to a surface below the unit. If the
4 1/8 inches to front wall, 1 inch to back and side walls,
Wooden and Metal Installation: DO NOT install closer than
1. Required Installation Clearances:
OUTLINED BELOW UPON INSTALLATION:
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
IS SUPPLIED FOR DM AND TDM MODELS ONLY.
THE DRAIN MANIFOLD WITH 1" INTERNAL NPT VALVE
NOTE:
CUTOUT DETAILS
INSTALLATION INSTRUCTIONS
37099-2 REV (-)
INSTALLATION INSTRUCTIONS
BUILT-IN MODULAR WARMERS
MOD 200 SERIES (T, TD, TDM)
12 AWB Cu
FIELD
WIRING
GAUGE
SINGLE
8.7
208
1800
MOD-200
AMPS
VOLTS
WATTS
MODELS
PHASE
12 AWB Cu
SINGLE
10.0
240
2400
MOD-200
14 AWB Cu
SINGLE
11.9
208
2480
MOD-200T
14 AWB Cu
SINGLE
13.8
240
3300
MOD-200T
(25)
(25)
(171)
(105)
MINIMUM CLEARANCE REQUIRED FROM
BACK
SIDE
BOTTOM
FRONT
1
1
6 3/4
4 1/8
ELECTRICAL
CLEARANCES
PRODUCT DIMENSIONS
UNIT TO THE NEAREST SURFACE
INCHES
(MM)